GPSMAP 6000/7000 Series Installation Instructions

Wiring Additional NMEA 0183 Devices

The NMEA 0183 data cable included with the GPSMAP 6000/7000 series chartplotter supports the NMEA 0183 standard, which is used to wire

various NMEA 0183-compliant devices, such as VHF radios, NMEA instruments, autopilots, or a computer.

Basic NMEA 0183 Wiring

These diagrams illustrate basic NMEA 0183 wiring used to connect your GPSMAP 6000/7000 series chartplotter to NMEA 0183-compliant

devices such as an AIS or DSC device. For more-complete information on the NMEA 0183 capabilities of the GPSMAP 6000/7000 series

chartplotter, see the “Advanced NMEA 0183 Wiring” section (

page 13)

.

Wiring to a NMEA 0183-compliant Device (AIS)

+

-

>

>

>
>

>

>

>

>

PINk

RECEIvE B(-)

Garmin

GPSMAP 6000/7000 series

chartplotter

NMEA 018-compliant

device

(AIS)

BAttERY

10–35 vdc

WIRE CoLoR

WIRE

RED (PoWER)

BLACk (PWR GND)

RED (PoWER)

FuSE

7.5 A - 42 v

BLACk (DAtA GND)

WHItE

oRANGE/WHItE

GRAY

tRANSMIt A(+)
tRANSMIt B(-)

RECEIvE A(+)

BLACk (PWR GND)
BLACk (DAtA GND)

PoWER

CABLE

NMEA 0183

CABLE

Wiring to a Single-ended NMEA 0183-compliant Device

+

-

>

>

>

>

>

>

Garmin

GPSMAP 6000/7000 series

chartplotter

NMEA 018-compliant

device

BAttERY

10–35 vdc

WIRE CoLoR

WIRE

RED (PoWER)

BLACk (PWR GND)

RED (PoWER)

FuSE

7.5 A - 42 v

BLACk (DAtA GND)

WHItE

oRANGE/WHItE

GRAY

PINk

BLACk (PWR GND)
BLACk (DAtA GND)

PoWER

CABLE

NMEA 0183

CABLE

tRANSMIt

RECEIvE

uNCoNNECtED

Notes:

If the NMEA 0183-compliant device has only one receiving wire (no A, B, +, or -), leave the pink wire unconnected.
If the NMEA 0183-compliant device has only one transmitting wire (no A, B, +, or -), connect the orange/white wire to ground.
Consult the installation instructions of your NMEA 0183-compliant device to identify the Transmit A(+) and B(-) wires and Receive A(+)

and B(-) wires.
Use 28 AWG, shielded, twisted-pair wiring for extended runs of wire.
Solder all connections and seal them with heat-shrink tubing.