8 optional accessories, 3 battery cable connections, 4 battery compartment – Guardian Technologies 004708-0 User Manual

Page 34: 1 remote start/stop panel, Figure 2.16 – connecting battery cables, Figure 2.17 – remote panel plug-in receptacle, Figure 2.18 – optional remote panel

Advertising
background image

32

2.7.3 BATTERY CABLE CONNECTIONS

‹

1. Connect the battery cable from the battery post or

terminal indicated by a POSITIVE, POS or (+) to
the lug on the starter contactor (Figure 2.16).

NOTE:

Check to be sure the battery cable boot for the
starter cable has been installed.

2. Connect the battery cable from the battery post

indicated by a NEGATIVE, NEG or (-) to the
frame ground connection (Figure 2.16).

3. Connect cables so the connectors are clean and

tight.

Figure 2.16 – Connecting Battery Cables

NEG

FUEL

POS

2.7.4 BATTERY

COMPARTMENT

‹

Install the generator battery in its own, vented com-
partment. Place the battery compartment away from
any source of heat, sparks or flame.

Provide ventilation openings in the battery compart-
ment. The minimum size of openings should be 2
square inches at the top of the compartment. Mount
the battery on a strong, rigid supporting structure,
where leaks and spills of battery fluid will not cause
damage.

2.8 OPTIONAL ACCESSORIES

A plug-in receptacle (Figure 2.17) is provided on
the generator set. Use this receptacle to connect an
optional remote-mounted start/stop panel to the
generator. Installation of such a panel will permit
starting and stopping the generator engine from any
convenient location inside the vehicle.

Figure 2.17 – Remote Panel Plug-in Receptacle

12.00"

14

0

17

15

18

14A

1

3

2

5

4

6

0

14

17

18

14A

15

15
17

14A

18

14

0

No.

WIRE

WIRE

COLOR

RED

YELLOW

ORANGE

WHITE

BLUE

BROWN

12.0 (305)

LENGTH (mm)

12.0 (305)
12.0 (305)
12.0 (305)
12.0 (305)
12.0 (305)

FUNCTION

GROUND

ENGINE RUN SIGNAL

12 VDC

START
STOP
PRIME

P/N: 0D9099-B

2.8.1 REMOTE START/STOP PANEL

‹

A remote mounted Start/Stop panel (Figure 2.18) is
available that allows the user to start and stop the
generator engine conveniently from inside the vehicle.
The remote panel includes a Start/Stop switch, hour-
meter, generator run lamp, a fuel prime switch, and
a wire harness. The hourmeter should be used in
conjunction with the maintenance operations found
in Part I of this manual.

Figure 2.18 – Optional Remote Panel

PRIME

FUEL

STOP

RUN

Section 2 – Installation

Recreational Vehicle Generator