Location, Installation instructions, The installation space – GE 197D7188P001 User Manual

Page 9: Side-by-side installations

Advertising
background image

23-3/4"

34-1/2"

25-1/2"

Locate
Outlet

34-1/2"-35"

24"

24" Min.

9" Max.

10-1/2"

1-1/2"

THE INSTALLATION SPACE

The cutout depth should be 24

The cutout dimensions shown allow for a full door swing and
access to the pull-out racks when installed as a built-in in
standard 24

″ deep cabinets.

• The door should protrude 2-1/4

″ beyond the surrounding

cabinets. For easy reference, the back edge of the pocket
handle should protrude a minimum of 5/8

″ beyond the

front edge of the countertop.

• If installing between frameless cabinets, a 1/2

″ wide

filler strip or side panel may be needed on hinge side.
The filler strip will act as a spacer between the case and
adjacent cabinet door swing. The width of the opening
must include the filler panels. NOTE: The door should
protrude 2-1/4

″ beyond the surrounding cabinets.

• The wine chiller and beverage center can be installed

freestanding.

Additional Specifications

• A 120 volt 60Hz., 15 or 20 amp power supply is required.

An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back
wall as shown. Electrical must be located on rear wall
as shown. NOTE: GFI (ground fault interrupter) is not
recommended.

Installation Instructions

9

Product dimensions:

Height: 34-1/2

″ (876 mm)

Width: 23-3/4

″ (603 mm)

Depth: 25-1/2

″ (647 mm)

Cut-out dimensions:

Height: 34-1/2–35

″ (876–889 mm)

Width: 24

″ (610 mm) minimum

Depth: 24

″ (610 mm) minimum

The wine chiller and beverage center can be a free-standing
model or it can be built in using the cut-out dimensions
below.

Increase storage capacity by installing two beverage centers
or wine chillers together. Or, for a complete refreshment
center, install any two of these units together.

• A side-by-side installation requires at least a 47-1/2

″ wide

opening. No trim kits required.

• Products must operate from separate, properly grounded

receptacles.

SIDE-BY-SIDE INSTALLATIONS

34-1/2"-35"

24"

47-1/2" Min.

1-1/2"

9"

10-1/2"

9"

10-1/2"

14"

15"

Locate

Outlet

Advertising
This manual is related to the following products: