Inserting the non-return flap 34, Inserting the non-return flap, Installation – Miele DA211 User Manual

Page 34: Attaching the motor assembly

Advertising
background image

Inserting the non-return flap

^ Air extraction:

If a non-return flap is not present in
the venting system, the

non-return

flap

supplied must be fitted into the

exhaust connection on the motor. The
flaps must open upwards.

^ The hood is designed for 6" (150 mm)

exhaust ducting. If 5" (125 mm)
exhaust ducting is used the

reducing

collar

must be fitted into the exhaust

connection on the motor (see "Air
extraction").

^ Recirculation mode:

The non-return flap is not required.

Attaching the motor assembly

^ First loosely screw the two locking

nuts onto the threaded bolts on
retaining plate A.
Leave a gap of

1

/

8

" (3 mm) for

hanging the motor on.

^ Fit the motor assembly onto the

hooks on retaining plate A and slide
down behind the nuts.

^ Tighten the nuts.

Installation

34

Advertising