Setting dial function selection (Pr. 53

)

Using the setting dial like a potentiometer to perform operation

Refer to

(page 94).

You can use the dial like a potentiometer to perform operation.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

53

Frequency setting
operation selection

0

0, 1

0: Setting dial

frequency setting
mode

1: Setting dial

potentiometer mode

Setting is
enabled when
Pr. 30 = "1"

POINT

•Set "1" (extended function parameter valid) in Pr. 30 "extended function display

selection".

•Set "1" (setting dial potentiometer mode) in Pr. 53 "frequency setting operation

selection".

Operation example Changing the frequency from 0Hz to 60Hz during operation

REMARKS

•If flickering "60.0" turns to "0.0", the Pr. 53 "frequency setting operation selection" setting

may not be "1".

•Independently of whether the inverter is running or at a stop, the frequency can be set by

merely turning the dial.

•When the frequency is changed, it will be stored as the set frequency after 10s.

Choose monitor/frequency monitor. ( )
The inverter must be in the PU operation mode.
(Press the .)
Pr. 30 must be set to "1".
Pr. 53 must be set to "1".

1.

PU

EXT

Mode/monitor check

RUN

PU

EXT

MODE

RUN

PU

EXT

RUN

3.

Turn the clockwise until
appears. The flickering frequency is
the set frequency.
You need not press the .

2.

Press the to start the inverter.

RUN

SET

Flickers for 3s.

Display

Operation

"60.0"