MITSUBISHI ELECTRIC FR-S520E User Manual

Page 114

Advertising
background image

104

Terminal function selection parameters

2.9.2

Output terminal function selection (Pr. 64

, Pr. 65

)

<Setting>

You can change the functions of the open collector output terminal and contact
output terminal.

Parameter

Name

Factory

Setting

Setting Range

Remarks

64

RUN terminal function
selection

0

0, 1, 3, 4, 11 to

16, 93, 95, 98, 99 Setting is enabled

when Pr. 30 = "1"

65

A, B, C terminal function
selection

99

0, 1, 3, 4, 11 to

16, 95, 98, 99

Setting

Signal

Name

Function

Operation

Parameters

Referred to

0

RUN

Inverter running

Output during operation when the
inverter output frequency rises to
or above the starting frequency.

Pr. 2, Pr. 13

1

SU

Up to frequency

Output when the output frequency
is reached.

Pr. 41

3

OL

Overload alarm

Output while stall prevention
function is activated.

Pr. 21, Pr. 22,
Pr. 23, Pr. 28

4

FU

Output frequency
detection

Output when the output frequency
rises to or above the setting.

Pr. 42, Pr. 43

11

RY

Inverter operation
ready

Output when the inverter is ready
to be started by switching the
start signal on.

12

Y12

Output current
detection

Output when the output current
rises to or above the setting.

Pr. 48, Pr. 49

13

Y13

Zero current detection

Output when the output current
reaches 0.

Pr. 50, Pr. 51

14

FDN

PID lower limit

Outputs the detection signal
under PID control.

Pr. 88 to Pr. 94

15

FUP

PID upper limit

16

RL

PID forward-reverse
rotation output

93

Y93

Current average value
monitor signal

The output current average value
and maintenance timer value are
output during the constant speed
operation. (can be set to the RUN
terminal (Pr.64) only)

H3 to H5

95

Y95

Maintenance timer
alarm

Output when maintenance
parameter H1 is greater than
maintenance parameter H2.

H1, H2

98

LF

Minor fault output

Output when a minor fault (fan
failure or communication error
warning) occurs.

Pr. 76, n5

99

ABC

Alarm output

Output when the inverter's
protective function is activated to
stop the output (major fault).

REMARKS

One function can be assigned to two terminals.