Communication specifications

Parameter

Name

Factory

Setting

Setting

Range

Remarks

Reflection

Timing

n1(331)

Communication station number

0

0 to 31

Setting is enabled
when Pr. 30 = "1"

After reset

n2(332)

Communication speed

192

48,96,192

After reset

n3(333)

Stop bit length

1

0,1,10,11

After reset

n4(334)

Parity check presence/ absence

2

0,1,2

After reset

n5(335)

Number of communication
retries

1

0 to 10,

- - -

Immediately

n6(336)

Communication check time
interval (*)

---

0, 0.1 to

999s, - - -

Immediately

n7(337)

Waiting time setting

---

0 to

150ms,

- - -

After reset

n11(341) CR/LF selection

1

0,1,2

After reset

POINTS

*

When making RS-485 communication, set any value other than 0 in the
communication parameter n6 "communication check time interval". RS-485
communication is disabled if the setting is "0s".

Item

Computer

Conforming standard

EIA-485 (RS-485)

Number of inverters
connected

1:N (max. 32 inverters)

Communication speed

Selected between 19200, 9600 and 4800bps

Control protocol

Asynchronous

Communication method

Half-duplex

C

o

mmu

n

ic

a

tio

n

sp

ec

if

ic

at

io

n

s

Character system

ASCII (7 bits/8 bits) selectable

Stop bit length

Selectable between 1 bit and 2 bits.

Terminator

CR/LF (presence/absence selectable)

Check
system

Parity check Selectable between presence (even/odd) and absence

Sum check

Presence

Waiting time setting

Selectable between presence and absence

REMARKS

•For computer link operation, set 65535 (HFFFF) as the value "- - -"and 65520 (HFFF0) as the

Pr. 19 value "888".

•Refer to page 46 for handling the RS-485 connector.

•For parameter instruction codes, refer to the appended parameter instruction code list (page

184).