4 interfaces, 1 com1 – rs232 (jack) 4-1, 2 com2 – rs232 (plug) 4-1 – MITSUBISHI ELECTRIC MITSUBISHI MAM MAM-AM24 User Manual

Page 21: Dip switches 4-3, 4interfaces, Com1, Com2

Advertising
background image

4

Interfaces

The serial interfaces COM1 und COM2 are to connect a PC, a PLC or other devices.

NOTE

The type and number of interfaces available depend on the type of modem being used.
(see section 2.6 and 10.6).

4.1

COM1 – RS232 (Jack)

The RS232 interface COM1 (9-pole D-Sub socket) is provided on all Mitsubishi Alarm Modem
models. It is primarily used as a programming interface for connecting a PC. A standard 1:1
serial cable can be used for this (not supplied)

.

4.2

COM2 – RS232 (Plug)

NOTE

As most PLCs require the use of a special serial programming cable, the programming cable
of Mitsubishi concerned should be used in all cases.

Interfaces

COM1 – RS232 (Jack)

Mitsubishi Alarm Modem

4 - 1

1 DCD

RTS 7

DSR 6

CTS 8

RI 9

2 RXD

3 TXD

4 DTR

5 GND

COM1

Fig. 4-1:
The COM1 port has the same assign-
ment as a standard modem with an
RS232 socket.

5 GND

CTS 8

RI 9

RTS 7

DSR 6

4 DTR

3 TXD

2 RXD

1 DCD

COM2

Fig. 4-2:
The assignment of the COM2 (plug) is
the same as that of a COM port on the
PC.