General Data

Technical data of the MAM series

Appendix

10 - 3

MITSUBISHI ELECTRIC

Feature

Data

Power supply

10 – 30 V DC, max. 0.7 A, screw terminal 2.5 mm² und power supply jack
(pin diameter 2 mm, inner diameter 6 mm).

LEDs

Power, Process, Line (connection), Data out, Modem Mode

Operating elements

Button

Housing/mounting

DIN-Rail Casing, for rail 35mm to EN50022,
vertical or horizontal

Conformity

GM series

,

EN 55022 (9:2003), EN 55024 (10:2003) EN 301489-1/7 (2000 GSM)

EN 60950

3GPP TS 51.010-1 (9:2002, v5.0.0.0) GCF-CC (10:2002, v3.8.1)

AM series

,

EN 55022 (9:2003), EN 55024 (10:2003)

, EN 60950

R&TTE-Policy TS 103021

Temperature
range

Operation

0 ... +50 °C

Storage

-30 ... +70 °C

Permissible
air humidity

5 to 95 % relative humidity, non-condensing

Degree of protection

IP20

Degree of pollution

Pollution degree 2

Dimensions

Width: 88 mm x Height: 57 mm x Depth: 91 mm (without antenna connection)

Weight

240g

Tab. 10-7: General data