Air extraction mode

Non-return flaps

^ Place the

non-return flaps

into the

exhaust connections at the top of the
motor assembly so that the flaps
open in the "up" direction.

^ Turn the non-return flaps slightly to

the left to lock them in place.

Reducing collar

^ If using 5" (125 mm) ducting, place

the reducing collars into the exhaust
connections and turn left to lock them
in place.

Exhaust connection

^ Connect the ductwork to the exhaust

connection using appropriate
measures for the type of ductwork
being installed (hose clamp, duct
tape, etc.).

Note:

A Y- adapter is supplied with the
DA 362-110. It may be used to feed the
exhaust from both connections to a
common duct.