OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

WARNING

EXCESSIVE AIR PRESSURE. Can cause personĆ

al injury, pump damage or property damage.

S

Do not exceed the maximum inlet air pressure as stated on the

pump model plate.

S

Be sure material hoses and other components are able to withĆ

stand fluid pressures developed by this pump. Check all hoses

for damage or wear. Be certain dispensing device is clean and

in proper working condition.

WARNING

STATIC SPARK. Can cause explosion resulting in

severe injury or death. Ground pump and pumping system.

S

Sparks can ignite flammable material and vapors.

S

The pumping system and object being sprayed must be

grounded when it is pumping, flushing, recirculating or sprayĆ

ing flammable materials such as paints, solvents, lacquers,

etc. or used in a location where surrounding atmosphere is

conducive to spontaneous combustion. Ground the dispensĆ

ing valve or device, containers, hoses and any object to which

material is being pumped.

S

Use the pump grounding screw terminal provided. Use Aro

Part No. 66885Ć1 Ground Kit or connect a suitable ground wire

(12 ga. min.) to a good earth ground source.

S

Secure pump, connections and all contact points to avoid

vibration and generation of contact or static spark.

S

Consult local building codes and electrical codes for specific

grounding requirements.

S

After grounding, periodically verify continuity of electrical path

to ground. Test with an ohmmeter from each component (e.g.,

hoses, pump, clamps, container, spray gun, etc.) to ground to

insure continuity. Ohmmeter should show 0.1 ohms or less.

S

Submerse the outlet hose end, dispensing valve or device in

the material being dispensed if possible. (Avoid free streaming

of material being dispensed.)

S

Use hoses incorporating a static wire.

S

Use proper ventilation.

S

Keep inflammables away from heat, open flames and sparks.

S

Keep containers closed when not in use.

WARNING

Pump exhaust may contain contaminants. Can

cause severe injury. Pipe exhaust away from work area and perĆ

sonnel.

S

In the event of a diaphragm rupture material can be forced out

of the air exhaust muffler.

S

Pipe the exhaust to a safe remote location when pumping hazĆ

ardous or inflammable materials.

S

Use a grounded 3/4" minimum i.d. hose between the pump and

the muffler.

WARNING

HAZARDOUS PRESSURE. Can result in serious

injury or property damage. Do not service or clean pump,

hoses or dispensing valve while the system is pressurized.

S

Disconnect air supply line and relieve pressure from the sysĆ

tem by opening dispensing valve or device and / or carefully

and slowly loosening and removing outlet hose or piping from

pump.

WARNING

HAZARDOUS MATERIALS. Can cause serious inĆ

jury or property damage. Do not attempt to return a pump to the

factory or service center that contains hazardous material.

Safe handling practices must comply with local and national

laws and safety code requirements.

S

Obtain Material Safety Data Sheets on all materials from the

supplier for proper handling instructions.

WARNING

EXPLOSION HAZARD. Models containing alumiĆ

num wetted parts cannot be used with III.ĆTrichloroethane, MeĆ

thylene Chloride or other Halogenated Hydrocarbon solvents

which may react and explode.

S

Check pump motor section, fluid caps, manifolds and all

wetted parts to assure compatibility before using with solvents

of this type.

CAUTION

Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or reĆ

circulated. Chemical compatibility may change with temperaĆ

ture and concentration of the chemical(s) within the

substances being pumped, flushed or circulated. For specific

fluid compatibility, consult the chemical manufacturer.

CAUTION

Maximum temperatures are based on mechaniĆ

cal stress only. Certain chemicals will significantly reduce

maximum safe operating temperature. Consult the chemical

manufacturer for chemical compatibility and temperature limĆ

its. Refer to PUMP DATA on page 1 of this manual.

CAUTION

Be certain all operators of this equipment have

been trained for safe working practices, understand it's limitaĆ

tions, and wear safety goggles / equipment when required.

CAUTION

Do not use the pump for the structural support of

the piping system. Be certain the system components are

properly supported to prevent stress on the pump parts.

S

Suction and discharge connections should be flexible connecĆ

tions (such as hose), not rigid piped, and should be compatible

with the substance being pumped.

CAUTION

Prevent unnecessary damage to the pump. Do

not allow pump to operate when out of material for long periods

of time.

S

Disconnect air line from pump when system sits idle for long

periods of time.

CAUTION

Use only genuine ARO replacement parts to asĆ

sure compatible pressure rating and longest service life.

NOTICE

Replacement warning labels are available upon

request: Static Spark PN \ 93616Ć1 & Diaphragm Rupture PN \

93122."

WARNING

CAUTION

NOTICE

= Hazards or unsafe practices which could

result in severe personal injury, death or

substantial property damage.

= Hazards or unsafe practices which could

result in minor personal injury, product

or property damage.

= Important installation, operation or mainĆ

tenance information.