If the error does not occur, connect one tape drive at a time back to the bus
and repeat step 3 for each tape drive until you can identify which drive is
defective.

Note: Ensure that the SCSI terminator is always on the last tape drive on the

SCSI bus.

4. Determine if the problem is with only one tape drive or with two or more tape

drives.

v

If the problem is with only one tape drive, run the SCSI wrap test on that tape
drive (see Function Code 6 in Table 9 on page 36).

– If the test runs successfully, replace the SCSI terminator first, then the

SCSI cable to that tape drive and interposer (if installed).

– If the test fails, replace the tape drive (see “Removing a SCSI Tape Drive

from an Enclosure” on page 83).

v

If the problem is with two or more tape drives, locate the first tape drive that
has the error and replace the SCSI cable that connects the tape drive and
the interposer (if installed).

Fixing an Intermittent Error with a Single Drive on a SCSI Bus

1. Replace the SCSI terminator on the tape drive.

2. Run the operation that caused the error. If the problem persists, the problem

may be with the cable.

3. Isolate which cable is causing the problem by replacing one cable at a time and

running the operation that caused the error after each replacement. If the
problem persists after all cables have been replaced, the problem may be with
the Ultrium 2 Tape Drive.

4. Replace the tape drive (see “Removing a SCSI Tape Drive from an Enclosure”

on page 83). If the problem persists, the problem is with your server. Consult

your server’s documentation.

Fixing an Intermittent Error with Multiples Drives on a SCSI Bus

Refer to the server’s error logs to determine which tape drive is the source of the
problem:

v

If only one tape drive is reporting a SCSI failure, replace that tape drive (see
“Removing a SCSI Tape Drive from an Enclosure” on page 83).

v

If multiple tape drives are reporting SCSI failures, the problem may be with the
terminator or the SCSI cables:

– Replace the terminator and run the operation that caused the error. If the

problem persists, the problem may be with the cables.

– Isolate which cable is causing the problem by replacing one cable at a time

and run the operation that caused the error after each replacement.