Specifications, Physical specification — small desktop model – IBM 6341 User Manual

Page 13

Advertising
background image

v Microsoft Windows 95
v Microsoft Windows NT

®

Workstation Version 4.0

v Microsoft Windows XP Personal and Professional

Specifications

This section lists the physical specifications for your computer.

Physical specification — small desktop model

Dimensions

Height: 88 mm (3.4 in.)

Width: 305 mm (12.0 in.)

Depth: 380 mm (14.9 in.)

Weight

Minimum configuration as shipped: 8.5 kg (18 lb)

Maximum configuration: 8.6 kg (19 lb)

Environment

Air temperature:

System on: 10° to 35° C (50° to 95° F)
System off: 10° to 43° C (50° to 110° F)

Maximum altitude: 2134 m (7000 ft)
Note:

The maximum altitude, 2134 m (7000 ft), is

the maximum altitude at which the specified air
temperatures apply. At higher altitudes, the
maximum air temperatures are lower than those
specified.

Humidity:

System on: 8% to 80%

System off: 8% to 80%

Electrical input

Input voltage:

Low range:

Minimum: 90 V ac

Maximum: 137 V ac

Input frequency range: 57–63 Hz

Voltage switch setting: 115 V ac

High range:

Minimum: 180 V ac

Maximum: 265 V ac

Input frequency range: 47–53 Hz

Voltage switch setting: 230 V ac

Input kilovolt-amperes (kVA) (approximate):

Minimum configuration as shipped: 0.08 kVA

Maximum configuration: 0.30 kVA

Note:

Power consumption and heat output vary

depending on the number and type of optional
features installed and the power-management
optional features in use.

Heat output

(approximate) in British thermal units (Btu)

per hour:

Minimum configuration: 188 Btu/hr (55 watts)

Maximum configuration: 256 Btu/hr (75 watts)

Airflow

Approximately 0.25 cubic meters per minute (9 cubic
feet per minute) maximum

Acoustical noise-emission values

Average sound-pressure levels:

At operator position:

Idle: 38 dBA

Operating: 43 dBA

At bystander position - 1 meter (3.3 ft):

Idle: 33 dBA

Operating: 37 dBA

Declared (upper limit) sound-power levels:

Idle: 3.75 bels

Operating: 4.99 bels

Note:

These levels were measured in controlled

acoustical environments according to the procedures
specified by the American National Standards
Institute (ANSI) S12.10 and ISO 7779 and are reported
in accordance with ISO 9296. Actual sound-pressure
levels in a given location might exceed the average
values stated because of room reflections and other
nearby noise sources. The declared sound-power
levels indicate an upper limit, below which a large
number of computers will operate.
Note:

The computer is classified as a Class A or Class

B digital device. See the Quick Reference for further
information about this classification.

Chapter 2. General Information