Keyboard/trackpoint related, Indicator related symptoms, Power related symptoms – IBM THINKPAD 760C/CD (9546) User Manual

Page 59: Keyboard/trackpoint related symptoms

Advertising
background image


Keyboard/TrackPoint Related
Symptoms

Symptom/Error

FRU/Action

Keyboard (one or more
keys) does not work.

1. Reseat the three

keyboard cables.

2. Keyboard
3. Keyboard Card
4. System Board

TrackPoint does not work.

1. Go to “TrackPoint III

Checkout” on
page 34.

2. Keyboard
3. Keyboard Card
4. System Board

Pointer moves automatically
or does not work correctly.

1. See “TrackPoint III

Checkout” on
page 34.

Indicator Related Symptoms

Symptom/Error

FRU/Action

Indicator incorrectly remains
off or on, but system runs
correctly.

1. Reseat the status

indicator cable.

2. Status Indicator
3. System Board

Battery power status
indicator blinks from green,
yellow, to orange.

1. Check that a correct

battery is installed.

2. Battery Pack
3. DC/DC Card
4. System Board

Power Related Symptoms

Symptom/Error

FRU/Action

Power shut down during
operation.

1. Go to “Power

Systems Checkout”
on page 35.

2. Battery Pack

3. Remove the battery

pack and let it cool for
two hours.

4. DC/DC Card
5. Power sources

The system will not
power-off.

1. Remove AC Adapter.
2. Remove the battery.
3. Wait 10 seconds.
4. Reconnect the AC

Adapter and try to
reproduce the error.

5. If the error remains,

replace the System
Board.

ThinkPad 365 (2625)