14

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

CAM TIMER OPERATION FOR HT-2 (CONTINUED)

FUNCTION: The rinse aid pump cam works off the normally closed contacts of cam 5. This requires the switch to be held open
by the cam and allowed to drop into the notch to operate the pump.

SETTINGS: The left side of cam 5 must be set to drop in just past the starting point of the fill cam. The adjustment for rinse aid
volume must be made with the right side of the cam.

CAM 6: Cam 6 is an adjustable cam and controls the detergent pump.

FUNCTION: The detergent pump cam works off the normally closed contacts of cam 6. This requires the switch to be held open
by the cam and allowed to drop into the notch to operate the pump.

SETTINGS: The left side of cam 6 must be set to drop in just past the starting point of the wash cam. The adjustment for deter-
gent volume must be made with the right side of the cam.