Alarm Input

Connect the cable to sensors such as infrared
sensors, door sensors, metal sensors and
manual switches.

Input Requirements

● Non-voltage relay NPN open collector input
● Polarity of input detection can be selected

using a software

● Make/break (500 ms and above)
● Circuit current of 1 mA during low-level input
● Applied voltage of 3.3 V during high-level

input

Alarm output

Connect to alarm devices such as alarm,
indicator, light or buzzer.

Output Requirements

● NPN open collector output equivalent (Refer

to the INSTRUCTIONS (Setting) on
procedures to set the output logic. )

● Allowable applied voltage: DC 12 V and

below

● Allowable inflow current: 50 mA
● Momentary (100 ms to 5000 ms) output

(Refer to [INSTRUCTIONS (Setting)] for
procedures to set the time. )

Note:

● Connect the GND cable of the camera to the

GND terminal of the alarm device.

Connecting the Alarm
Input/Output Cable

DC3.3 V

R

3.3 V

1 mA

VCC

OUT

GND

GND

OUT

R

GND

(Alarm input equivalent
circuit)

Input 1 or
Input 2

This unit

Sensor example

(1)

Sensor example

(2)

Relay switch, etc.

IN

R

DC 12 V

GND

GND

Alarm device

(example)

This unit

(Alarm output equivalent
circuit)

Output 1 or
Output 2