5 regulation of primary air, Instructions for the installer, Referred to distance “ a ” in mm – Smeg GKC95-3 User Manual

Page 12: Rapid large (4) 0 2.5

Advertising
background image

Instructions for the installer

34

5.5

Regulation of primary air

Referred to distance “A” in mm.

60 cm hobs with separable control panel.

Burner

G25

25 mbar

G30/G31

28/37 mbar

Auxiliary (1)

2.5

2.5

Semirapid r (2)

0.5

2.0

Semirapid l (3)

0.5

1.5

Rapid large (4)

0

2.5

Ultrarapid (5)

2.0

4.0

90 cm hobs with separable control panel.

Burner

G25

25 mbar

G30/G31

28/37 mbar

Auxiliary (1)

2.0

2.5

Semirapid (2)

0.5

2.0

Rapid (3)

-0.5

1.5

Fish burner (4)

-1.0

8.0

Ultrarapid (5)

1.5

5.5

60 cm hob with built-in control panel.

Burner

G25

25 mbar

G30/G31

28/37 mbar

Auxiliary (1)

2.5

2.5

Semirapid r (2)

0.5

2.5

Semirapid l (3)

0.5

2.0

Rapid medio (4)

0.0

2.5

Ultrarapid (5)

1.0

3.0

To identify the burners on your hob, refer to the drawings in point “6.3/6.4