Adaptation to different types of gas, 1 removing the hob, Adaptation – Smeg CIR574X User Manual

Page 10: Different types of gas, Instructions for the installer

Advertising
background image

Instructions for the installer

12

5. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, detach the

appliance from the electrical socket.

The hob has been adjusted for natural gas at a pressure of 1.0kPa.
For functioning with other types of gas the nozzles must be replaced and
the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove the
top as described in the following paragraph.

5.1 Removing the hob

1.

Remove all the knobs, the grids, the burner caps and the flame-caps;

2.

remove the screws and the nuts A that secure the burner supports;

3.

remove plates B;

4.

lift the hob from its seat;

5.

replace the burner nozzles in accordance with the reference gas
chart;

6.

regulate the primary air as described in paragraph “5.2 Adjustment
for LPG
”.