SAFETY RELATED ADJUSTMENT

When replacing the following components marked with

] on

the schematic diagram, always check hold-down voltage and if

necessary re-adjust.

4-1. HV HOLD-DOWN ADJUSTMENT

1. Remove CN810. Connect HV meter to HV Block.
2. Connect External Power Supply to CN810 2 pin

(+135V) and 1 pin (GND).

Part Replaced (

])

E Board

C515,

C516,

C554,

D504,

D507,

L506,

Q502,

R1,

R514,

R516,

R517,

T502,

T504 (FBT)

G Board

IC6008

Part Replaced (

[)

R1

3. Turn on the set.
4. Slowly up the supply voltage from 0V to 135V.
5. Receive dot picture and set PICTURE/BRIGHTNESS to

minimum.

6. Slowly up the voltage until hold-down circuit works (pic-

ture disappear).

7. Read the HV meter of peak HV voltage.

Spec: 34.5

±

0.75KV

8. If Hold-down voltage is less than 33.75KV then solder

R1=820K.

9. If hold-down voltage is over than 35.25KV then take-off

R514 and solder R1=9.1K.

+

2

CN810

Power
Supply

1

E BOARD

– CONDUCTOR SIDE –

CN810

CN505

CN505

R1

Fig. 4-1

Fig. 4-2

Fig. 4-3

Fig. 4-4

Remove the cap off
from the unused
terminal and connect a
static voltmeter there.