Eclipse, Spectral sensitivity characteristics, Vibration specifications – Sony FCB-IX11A User Manual

Page 11: 11 basic functions

Advertising
background image

11

Basic Functions

Spectral Sensitivity
Characteristics

Vibration
Specifications

Test Method (Random vibration)

• Fix the camera at the four fixation points of the base

using M2 screws.

• Perform the random vibration test under the

following conditions in the X, Y and Z directions for
20 minutes in each direction.

• The camera vibration specification is to have no

malfunction after this test.

Power spectrum density

Effective overall value

Test time

5 to 50 Hz

4.14 m

2

/s

3

{0.043 G

2

/Hz}

50 to 100 Hz

–36 dB/oct

14.3 m/s

2

{1.46 G}

20 minutes

30.97˚

8.92

Eclipse

When designing the housing, refer to the dimensional
allowance as shown in the figure below.

9.56

21.82˚

1

Ye

Cy

G

Mg

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

400

500

600

700

800

900

1000

Wave Length [nm]

Relativ