Scanner control dialog box, Multi-feed detection options – Kodak i55 User Manual
Page 69
 
A-61527 May 2006
65
Scanner Control 
dialog box
Selecting the Scanner Control button on the More Scanner Settings 
dialog box displays the Scanner Control dialog box. 
This dialog box allows you to set multi-feed detection and transport 
control. The settings in this dialog box do not affect the quality of the 
image. 
OK
 saves the values set on the dialog box.
Cancel
 closes the dialog box without saving any changes.
Multi-Feed Detection 
options
Length Detection
 this option can be enabled or disabled. The
default is disabled. If Length Detection is enabled, enter the maximum 
length. This is the minimum length of the document that can be 
scanned with a multi-feed being detected. Length detection is used 
when scanning same-sized documents to check for overlap. For 
example, if you are scanning 8.5 x 11-inch (A4) documents in portrait 
mode, you may want to enter a value of 11.25 inches (28.57 cm) in the 
Maximum Length field. 
Units — defines the primary measurement system. Pixels, Inches, 
and Centimeters are available.
Auto Set
 when enabled, will automatically set the maximum length
value to .50-inch (1.27 cm) greater than the length of the currently 
selected page size.
Stop scanner on Multi-Feed — when enabled, the scanner will stop 
when a multi-feed is encountered. 
Sound Alarm on Multi-Feed — when enabled, the scanner will alert 
you with the sound you selected when a multi-feed is encountered.
Sound — select this option to choose the sound you would like your 
PC to make to alert you of a multi-fed document. 
To choose a sound:
1. Click on the Sound button to display the Open dialog box.
2. Choose the desired .wav file.
3. Click Open on the dialog box and the sound will be saved.