R]kfc-241-2, Fiber optical specifications, Ordering informations – KTI Networks KC-300D User Manual

Page 2: Model connector fiber, Wavelength tx power, Rx sens. rx max

Advertising
background image

120525

Dimension

KFC-241-L: 34 x 49 x 56mm (WxDxH)

KFC-241-H: 45.5 x 49 x 56mm (WxDxH)

Mounting Support

DIN-Rail, Panel

Environment

Operating temperature: -30

O

C ~ 70

O

C (Main device)

Storage temperature:

-40

O

C ~ +85

O

C

Relative Humidity:

10%~90% non-condensing

Certification

FCC Class A, CE mark Class A, LVD, TUV IEC 60950-1 safety, C-Tick

Fiber Optical Specifications:

Model Connector Fiber

1

Wavelength

Tx Power

2

Rx Sens. Rx Max.

-T

Duplex ST

MMF

1310nm

-20 ~ -14dBm

-32dBm

-8dBm

-C

Duplex SC

MMF

1310nm

-20 ~ -14dBm

-31dBm

0dBm

-SL2

Duplex SC

SMF

1310nm

-15 ~ -8dBm -30dBm -7dBm

-SL3

Duplex SC

SMF

1310nm

-15 ~ -8dBm

-34dBm 0dBm

-SL6

Duplex SC

SMF

1310nm

-5 ~ 0dBm

-35dBm 0dBm

-W3520 BiDi SC

SMF

Tx 1310nm

-14 ~ -8dBm

-31dBm 0dBm

Rx 1550nm

-W5320 BiDi SC

SMF

Tx 1550nm

-14 ~ -8dBm -31dBm

0dBm

Rx 1310nm

1

MMF: Multimode fiber - 62.5/125 µm, 50/125 µm

SMF: Single Mode fiber - 9 /125 µm

2

Data for 62.5/125µm MMF, 9 /125µm SMF

FCC Part 15' Class A

CISPR 22 Class A

Katron Technologies Inc.

15F-7, No. 79, Sec. 1, Hsin Tai Wu Rd.,
Hsi-chih District, New Taipei City, Taiwan
Te l : 886-2-2698-3878
Fax : 886-2-2698-3873
E-mail : [email protected]
URL : http : //www.ktinet.com.tw

KTI Networks Inc.

10415-A Westpark Drive, Houston,
TX 77042. U.S.A.
Te l : 1-713-266-3891
Fax : 1-713-914-0555
E-mail : [email protected]
URL : http : //www.ktinet.com

Trademarks : All brand names are trademarks or registered
trademarks of their respective holders.
This information is subject to change without prior notice.

KFC-241-H with DIN-Rail bracket

KFC-241-L with DIN-Rail bracket

KFC-241-H with Panel mounting bracket KFC-241-L with Panel mounting bracket

Ordering Informations:

KFC-241-H-x

KFC-241-L-x

Model

DC IN

DC IN Voltage

TB-3P, DC Jack

TB-3P

+4.5 ~ 50VDC

+110VDC

MM: Multimode Fiber
SM: Single Mode Fiber
Ref. Distance: Reference connection distance

MM

MM

Fiber

Mode

SM

SM

SM

SM

SM

Ref.

Distance

2km

2km

60km

20km

30km

20km

20km

KFC-241-L-x

KFC-241-H-x

-T

-C

-SL6

-SL2

-SL3

-W3520

-W5320

Duplex ST

Duplex SC

Connector

Duplex SC

Duplex SC

Duplex SC

BiDi SC

BiDi SC

EMI EMS Safety Environmental Tests:

Specifications

Class A

Class A

< 75 W

Clause 5

Contact: +/-6KV

Air: +/-8KV

Strength: 10V/m

DC IN: +/-1KV

RJ-45: +/-0.5KV

Test

FCC/EMI

CE/EMC/EMI

CE/EMC/Harmonic

CE/EMC/VFF

CE/EMC/EMS

ESD Test

RS Test

EFT/BURST

Standard

FCC Rule Part 15

EN55022, CISPR 22

EN 61000-3-2

EN 61000-3-3

EN 55024

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-4

Level 3

50Hz 100A/m

Interruption: C

Dips: B

DC IN: +/-0.5KV

RJ-45: +/-1KV

TP, 1500VAC/60sec.

TP, 500VDC/10Mohm

-30

O

C, 96hrs

+70

O

C 40%RH 72hrs

+60

O

C 90%RH 72hrs

Surge Immunity

CS Test

Magnetic Field Imm.

Voltage Dips Imm.

Safety

Dielectric Voltage

Insulation Resistance

Cold Test

Dry Heat Test

Damp Heat Test

Storage Test

Vibration Test

IEC 61000-4-5

IEC 61000-4-6

IEC 61000-4-8

IEC 61000-4-11

EN 60950, IEC 60950

IEEE 802.3

IEEE 802.3

IEC 68-2-1 Test Ad

IEC 68-2-2 Test Bd

IEC 68-2-3

IEC 68-2-48

IEC 68-2-34

+85

O

C 40%RH 96hrs

-40

O

C 96hrs

Advertising
This manual is related to the following products: