Desktop placement, Rack-mount placement, Hardware installation – Linksys Business Smart Gigabit Ethernet Switch SLM2048 User Manual

Page 14: Desktop placement rack-mount placement, Chapter, Installation

Advertising
background image

9

Installation

Business Series Smart Gigabit Ethernet Switch

Chapter 

Desktop Placement

Attach the rubber feet to the recessed areas on the

bottom of the Switch.
Place the Switch on a desktop near an AC power

source.
Keep enough ventilation space for the switch and

check the environmental restrictions mentioned in the

Specifications Appendix as you are placing the Switch.
Connect the Switch to network devices according to

the Hardware Installation instructions below.

Attaching the Switch’s Rubber Feet

Rack-Mount Placement

When rack-mounting the Switch, please observe the

following guidelines

Elevated Operating Ambient

If installed in a closed

or multi-unit rack assembly, the operating ambient

temperature of the rack environment may be greater

than room ambient. Therefore, consideration should

be given to installing the equipment in an environment

compatible with the maximum ambient temperature

(Tma) specified by the manufacturer.

Reduced Air Flow

Installation of the equipment

in a rack should be such that the amount of air flow

required for safe operation of the equipment is not

compromised.

Mechanical Loading

Mounting of the equipment in

the rack should be such that a hazardous condition is

not achieved due to uneven mechanical loading.

Circuit Overloading

Consideration should be given

to the connection of the equipment to the supply

circuit and the effect that overloading of the circuits

might have on overcurrent protection and supply

wiring. Appropriate consideration of equipment

nameplate ratings should be used when addressing

this concern.

Reliable Earthing

Reliable earthing of rack-mounted

equipment should be maintained. Particular attention

should be given to supply connections other than

direct connections to the branch circuit (e.g. use of

power strips).

To rack-mount the Switch in any standard 19-inch wide,

1U high rack, follow the instructions described below.

Place the Switch on a hard flat surface with the front

panel facing you.
Attach a rack–mount bracket to one side of the Switch

with the supplied screws and secure the bracket

tightly.

Attaching the Brackets

Follow the same steps to attach the other bracket to

the opposite side.
After the brackets are attached to the Switch, use

suitable screws to securely attach the brackets to any

standard 19-inch rack.

Mounting in Rack

Connect the Switch to network devices according to

the Hardware Installation instructions below.

Hardware Installation

To connect network devices to the Switch, follow these

instructions:

Make sure all the devices you will connect to the Switch

are powered off.
For a 10/100 Mbps device:

All models: Connect a Category 5 Ethernet network

cable to one of the numbered ports on the Switch.

1.

2.

3.

4.

5.

1.

2.