4 error when no atmospheric correction is made – Pentax R-315(N) User Manual

Page 84

Advertising
background image

82

13 APPENDIX

13-4 Error when no Atmospheric Correction is made

When measurement is carried out with no Atmospheric Correction (with the
settings fixed at a temperature of 15°C and an atmospheric pressure of 1013 hPa
or 760 mmHg), the Error per 100 meters in temperature and pressure will be
shown in the tables below.

●

When the actual pressure is 1013 hPa (760 mmHg) and the temperature is
25°C, conducting the measurement with the temperature left at 15°C will
result in the measurement being short by 0.9 mm per 100 meters.

Error table: When hPa (15°C, 1013hPa as standard)

Unit:mm

hPa

1200

1100

1013 900

800

700

600

500

C°

45

2.0

-0.5

-2.6

-5.5

-8.0

-10.5

-13.0

-15.5

35

3.0

0.4

-1.8

-4.7

-7.3

-9.9

-12.5

-15.1

25

4.0

1.4

-0.9

-4.0

-6.6

-9.3

-12.0

-14.6

15

5.2

2.4

-0.0

-3.1

-5.9

-8.6

-11.4

-14.2

5

6.3

3.5

1.0

-2.2

-5.1

-8.0

-10.8

-13.7

-5

7.6

4.7

2.1

-1.3

-4.2

-7.2

-10.2

-13.1

-15

9.0

5.9

3.2

-0.2

-3.3

-6.4

-9.5

-12.6

Error table: With mmHg (15°C, 760mmHg as standard)

Unit:mm

mmHg

900

800

760

700

600

500

400

C°

45

2.0

-1.3

-2.6

-4.6

-8.0

-11.3

-14.6

35

3.0

-0.4

-1.8

-3.9

-7.3

-10.8

-14.2

25

4.0

0.5

-0.9

-3.1

-6.6

-10.2

-13.7

15

5.2

1.5

0.0

-2.2

-5.9

-9.6

-13.3

5

6.3

2.5

1.0

-1.3

-5.1

-8.9

-12.7

-5

7.6

3.7

2.1

-0.3

-4.2

-8.2

-12.2

-15

9.0

4.9

3.2

0.8

-3.3

-7.4

-11.5

PENTAX R-300 (p65-88) 10/30/02 11:11 AM Page 82

Advertising
This manual is related to the following products: