Connections, Video cable, Alarm connections – Panasonic WV-CP474 User Manual

Page 3

Advertising
background image

Copper wire

#24

#22

#20

#18

size (AWG)

(0.22mm

2

) (0.33mm

2

) (0.52mm

2

) (0.83mm

2

)

Length

(m)

95

150

255

425

of Cable
(Approx.) (ft)

314

495

842

1 403

Video Cable

1. It is recommended to use a monitor

whose resolution is at least equal to
that of the camera.

2. The maximum extensible coaxial

cable length between the camera
and the monitor is shown in the
table.

Cautions:

1. Connect to 12 V DC (10.8 V - 16 V) or 24 V AC (19.5 V - 28 V) class 2 power supply

only. Be sure to connect the grounding lead to the GND terminal when the power is
supplied from a 24 V AC power source.

2. To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007) for

the Input Terminal.

!6

Day/Night Input Terminal (DAY/NIGHT IN/GND)

This terminal is used for connecting the camera to an external day/night detecting sen-
sor.

!7

AC Inlet Socket

Plug the power cord (supplied as a standard accessory) into this socket and connect it
to an AC outlet.

!8

AC/DC Compatible Input Terminal
(DC 12 V IN/AC 24 V IN)

This terminal is for connecting the 12 V DC or 24 V AC power supply cord.

Note:

Do not exceed the ratings of the voltage or current when connecting the external

device.

CONNECTIONS

A. WV-CP470 (120 V AC 60 Hz)

Plug the AC power cord (supplied as standard accessory) into the AC inlet socket and con-
nect it to a 120 V AC 60 Hz outlet.

Notes:

• Connect the power cord firmly.
• The power cord should be long enough for panning and tilting.

If the cable is too short, the power cord plug may be pulled off the camera when the
camera pans or tilts.

B. WV-CP474 (12 V DC/24 V AC)

The WV-CP474 has an AC/DC compatible input terminal. The 12 V DC or 24 V AC power
supply cord can be connected to this terminal. The camera detects the power source auto-
matically.

1

2

GND

1

2

AC 24V IN

DC 12V IN

12 V DC
(10.8 V - 16 V)

Copper wire

#24

#22

#20

#18

size (AWG)

(0.22mm

2

) (0.33mm

2

) (0.52mm

2

) (0.83mm

2

)

Resistance

0.078

0.050

0.030

0.018

/m

Resistance

0.026

0.017

0.010

0.006

/ft

Resistance of copper wire [at 20 °C (68 °F)]

• Calculation of maximum cable length between camera and power supply

10.8 V DC

V

A

- (R x 0.42 x L)

16 V DC

L : Cable length (m)
R : Resistance of copper wire (

/m)

V

A

: DC output voltage of power supply

unit

2. 24 V AC Power Supply

Connect the power cable to the AC/DC compatible input terminal on the rear panel of
the camera.

Recommended wire gauge sizes for 24 V AC line.

1

2

GND

GND

1

2

AC 24V IN

DC 12V IN

24 V AC, 60 Hz
(19.5 V - 28 V)

Caution:

To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007).

1. 12 V DC Power Supply

Connect the power cord to the AC/DC compatible input terminal on the rear panel of the
camera.

Type of

RG-59/U

RG-6U RG-11/U RG-15/U

coaxial cable

(3C-2V)

(5C-2V) (7C-2V)

(10C-2V)

Recommended (m)

250

500

600

800

maximum
cable length

(ft)

825

1 650

1 980

2 640

V

A

12

L standard =

(m)

0.42 x R

V

A

16

L minimum =

(m)

0.42 x R

V

A

10.8

L maximum =

(m)

0.42 x R

Alarm Connections

1. Connect an external sensor to the DAY/NIGHT terminal.
2. Connect an external device such as a buzzer or lamp to the ALARM terminal.

• The alarm output terminal is an open collector terminal with a capacity of 16 V DC, 100

mA or less.
OFF: Open contact
ON: 100 mA or less

• Color/black-and-white input terminal with a capacity of 5 V DC pull-up input, 0.2 mA or

more.
OFF: Open contact
ON: Closed contact

Notes:

• Use a relay unit if the voltage or current of the connected device exceeds the ratings.
• To validate the Day/Night function, set BW mode to EXT on the special menu.