INSTALLATION

(SUSPENDED BETWEEN JOIST MOUNTING)

1. Before installation, secure the lighting unit to fan body

(refering to Fig.5 of page 10).

2. Insert the suspension bracket into bracket cover of

adaptor side and the back of the fan body.

(Fig.15-1,15-2)

(select the suspension bracket according to spacing A

as shown below.)

16 inches and 19.2 inches

horizontal joist

Suspension bracket

I

Suspension bracket

I

Suspension bracket

III

Suspension bracket

III

Suspension bracket

II

Suspension bracket

II

16 inches and 19.2 inches

horizontal joist

19.2 inches vertical joist

Fig.15-1

Fig.15-2

Fig.16

Fig.17

Fig.18

Joist

2 Long screws (ST4.2X20)

4 Long screws (ST4.2X20)

2 Screw
(ST4.2X12)

II

Joists

Adaptor

Junction box

Fan body

5/8 (15.9)

3. Insert the fan body between joists. Make sure the fan

body is level and square (perpendicular) with the joists.

(Fig.16)

If installing with fan body flange below drywall, keep

the distance B (1/ inch, 12.7mm or 5/8 inch, 15.9mm)

for the thickness of ceiling board.

2

4. Secure the suspension bracket to joists by using long

screws (ST4.2X20) (Fig.17, Fig.18)

5. Secure the suspension bracket to fan body by using

screw

(ST4.2X12) (Fig.18)

II

6. Follow steps 4 to 12 of installation (page 9, page 10)

to complete the installation work.

I

13

Inches(mm)

13 1/4 15 3/4 (336 400)

~

~

16 1/2 18 3/4 (419 480)

~

~

3 5

( 76 126)

5 4/5 7 4/5 (148 198)

~

~

~

~

1/2 (12.7)

PDF created with pdfFactory Pro trial version