Fig.6 esd clamping test set-up and waveforms – Philips BZA800AL Series User Manual

Page 5

Advertising
background image

2002 Jan 11

5

NXP Semiconductors

Product data sheet

Quadruple ESD transient voltage
suppressor

BZA800AL series

handbook, full pagewidth

MLD794

450

50

Note 1: attenuator is only used for open
socket high voltage measurements

IEC 61000-4-2 network
CZ = 150 pF; RZ = 330

1/4 BZA800AL

RG 223/U
50

coax

RZ

CZ

ESD TESTER

DIGITIZING

OSCILLOSCOPE

10

×

ATTENUATOR

note 1

GND

GND

GND

unclamped

+

1 kV ESD voltage waveform

(IEC 61000-4-2 network)

clamped

+

1 kV ESD voltage waveform

(IEC 61000-4-2 network)

vertical scale = 100 V/div
horizontal scale = 50 ns/div

unclamped

1 kV ESD voltage waveform

(IEC 61000-4-2 network)

clamped

1 kV ESD voltage waveform

(IEC 61000-4-2 network)

vertical scale = 100 V/div
horizontal scale = 50 ns/div

vertical scale = 5 V/div
horizontal scale = 50 ns/div

vertical scale = 5 V/div
horizontal scale = 50 ns/div

BZA868AL

BZA862AL

BZA856AL

Fig.6 ESD clamping test set-up and waveforms.