OPERATING AND USER INSTRUCTIONS

THIS APPLIANCE HAS BEEN DESIGNED FOR
STORAGE OF FOODS, STORAGE OF FROZEN
FOODS, AND MAKING ICE WHEN INSTALLED AS
DIRECTED BY THIS MANUAL.

Location of Controls

Figure 18 illustrates the location of the 400 Series

refrigerator’s operating controls. All operating controls
are conveniently located below the door.

Operating Controls Function

Ignition Switch

The ignition switch is used for the Gas operation

only. When the ignition switch is turned "ON", the
switch will illuminate indicating that 12 volt DC is
available and being supplied to the electronic ignition
which generates ignition spark to the burner.

Flame Indicator Lamp

When a flame is established at the burner, the

Flame Indicator Lamp will illuminate indicating the re-
frigerator is operating on gas.

Thermostat

The thermostat controls all modes of operations,

thereby eliminating the necessity of resetting each
time a different power source is selected. Rotate the
knob clockwise to make the refrigerator cabinet
colder.

Gas ON/Electric and Safety Valve

Gas ON/ELECTRIC allows the user to select an

operating mode. For gas, push and turn the knob
counter-clockwise until the knob is pointing to "GAS".

For AC electric, push and turn clockwise until the
knob is pointing to"ELEC". Note, upon release the
knob will move towards you, indicating that the oper-
ating control is locked into the AC electric mode.

Safety Valve - During the gas ignition process, the

safety valve knob must be held in until a flame is
established at the burner.

The safety valve is designed so that any loss of

flame will stop the gas flow to the burner. It is con-
trolled by means of a thermocouple that is positioned
in the flame. As long as a flame is detected by the
thermocouple, the valve will remain open. Upon
flame failure, the valve closes, shutting off the gas
flow to the burner.

AC/DC Selector Switch

This switch is utilized on 3-Way models only. The
switch selects either 120 volt AC or DC electric
modes of operation. The center position of the switch
is a "Stand-By" mode which will temporarily turn off
the electric positions.

Gas Operation

The gas burner is designed to operate on propane

gas only. The gas control is equipped with an ignition
relighter, offering the features of automatic re-ignition
in case of flame blowout, positive flame sensing, and
easier gas start-up. The ignition relighter is powered
by 12 volts DC and is controlled by the ignitor switch
located on the control panel. When the switch is in
the "OFF" position, no ignition spark is present.
When the switch is in the "ON" position, the relighter
produces a rapid spark at the gas burner. The spark
occurs at a rate of 1 to 2 times per second until a
flame is present (Refer to "Lighting Instructions").
The spark continues until a flame is sensed or until
the ignitor switch is turned off. When the flame is
sensed, the relighter discontinues the spark and the
flame indicator illuminates. The flame indicator lamp
will cease to illuminate upon loss of burner flame.
During gas operation, the current draw for the re-igni-
tion system is very low, approximately 30 milliamps
(.030 amps).

120 Volt AC Operation

While parked, the coach normally operates from a

120 volt AC source. The refrigerator can be very eas-
ily switched to AC operation.

!2 Volt DC Electric Operation

The refrigerator receives its DC power from the ve-

hicle’s 12 volt system; either an auxiliary battery, a
converter, or the engine battery. The 12 volt DC sys-

Ignition Switch

Flame
Indicator Lamp

Thermostat

Gas On/Electric
and Safety Valve

AC/DC Selector Switch
3-Way Models Only

Figure 20