System Unit

Tower Dimensions
(HxWxD)

19.5 x 11.7 x 26.5 in (49.5 x 29.7 x 67.3 cm)

Weight
(tower configuration)

Minimum Tower Configuration 49.4 lb (22.4 kg)

Maximum Tower Configuration 56.3 lb (25.5 kg)

Rack Dimensions (HxWxD) 3.4 x 19.0 x 26.8 in (8.6 x 48.3 x 68.1 cm)

EIA Units

2U (20 units possible per 2 meter rack)

Weight (rack configuration)

Minimum Rack Configuration

38.6 lb (17.5 kg)

Maximum Rack Configuration

49.0 lb (22.2 kg)

Power Supply

Input current (autoranging)

8.0A max @ 100-127V, 3.9A max @ 200-240V

Line Frequency

50- 60 Hz

Maximum Power Input

714 W

Temperature

Operating

41° to 95° F (5° to 35° C)

Non-operating

-40° to 158° F (-40° to 70° C)

Humidity
(non-condensing)

Operating

15% to 80% relative

Maximum Altitude
(non-pressurized)

Operating

10,000 ft (3,048 m)

Non-operating

15,000 ft (4572 m)

HP Keyboard

Dimensions (HxWxD)

18.82 x 7.3 x 1.85 in (47.8 x 18.6 x 4.7 cm)

Weight

Approx.1.2 kg ± 0.1 kg

Electrical

Operating Voltage

+ 5VDC ± 5%

Power Consumption

60 mA maximum (with 3 LEDs on)

System Interface

USB connector

ESD

CE level 4, 15 kV air discharge

EMI-RFI

Conforms to FCC rules for a Class B computing device

PC98

Functionally compliant

Mechanical

Languages

12 available

Keycaps

Standard profile design

Switch Actuation

55 g nominal peak force with tactile feedback

Switch Life

20 million keystrokes (using Hasco modified tester)

Switch Type

Contamination resistant membrane

Key Leveling Mechanism

For all double wide and greater length keys

Cable Length

2.9 m

PC98-99

Mechanically compliant

Acoustics

65 dBA for spacebar, 55 dBA for all others maximum
sound pressure level

Environmental

Operating Temperature

41° to 95° F (5° to 35° C)

Non-operating Temperature

-40° to 140° F (-40° to 60° C)

Operating Humidity

10% to 80% (non condensing at ambient)

Non-operating Humidity

10% to 90% (non condensing at ambient)

Operating Shock

40 g, 6 surfaces

Non-operating Shock

80 g, 6 surfaces

Operating Vibration

2 g peak acceleration

Non-operating Vibration

4 g peak acceleration