Panasonic WV-CW500S/G User Manual

Page 17

Advertising
background image

17

Step 6

Set the detection sensitivity and the minimum size of objects detected. Perform the setup while viewing the detection result displayed
on the screen.

Set the detection sensitivity
Move the cursor to "SENSITIVITY" and select one of the following options for the detection sensitivity:
LOW (default)/MID/HIGH

Set the minimum size of objects detected
Move the cursor to "MIN SIZE" and select the minimum size of objects detected from the following: The size options will be displayed
in a green frame in the center of the screen. In "OFF" position, any object will be detected regardless of its size.
Perform the setup while viewing the detection result displayed on the screen.
OFF (default)/SMALL/MEDIUM/LARGE

Note:

• The detection sensitivity and minimum size selected in this step will be applied to all the alarm actions selected in step 3.
• The detection areas set in step 4 will be displayed as a white frame on the "SENSITIVITY" screen.
• When a motion is detected, a blue frame appears and changes to a red frame after a given time (approx. 1 second.) on the

"SENSITIVITY" screen. In operation, an alarm signal is provided when the frame changes to red.

Perform the settings relating to the detection of appearance/disappearance of stationary objects

Perform the settings relating to the detection of appearance/disappearance of stationary objects as follows. Up to 4 appearances/
disappearances of stationary objects can be simultaneously detected. However, use of the scene change detection function
decreases the maximum simultaneous detectable appearances/disappearances of stationary objects to 3.
Follow the procedure below.

Step 1

Move the cursor to "i-VMD" and press the setting button.

→ The "i-VMD SETUP" screen appears.

Step 2

Move the cursor to "OBJECT DET" and press the setting button.

→ The "OBJECT DET" screen appears.

Step 3

Move the cursor to "DURATION TIME" and select the wait time of appearance/disappearance of stationary objects from the following.
10 s (default)/20 s/30 s/40 s

**CAMERA SETUP**

SCENE1

ALC ALC

SHUTTER OFF

AGC ON(HIGH)

SENS UP OFF

WHITE BAL ATW1

DNR HIGH

BW MODE AUTO1

i-VMD

RET TOP END

"i-VMD SETUP" screen

"OBJECT" screen

"SENSITIVITY" screen

"CAMERA SETUP" screen

**i-VMD SETUP**(1)

MOTION DET

OBJECT DET ON

SCENE CHANGE OFF
INDICATOR OFF

ALARM CONT

RET TOP END

**SENSITIVITY**(1)

MIN SIZE OFF

RET TOP END

**OBJECT DET**(1)

REMOVAL AND LEFT BEHIND
DURATION TIME 10s

AREA ALL

SENSITIVITY

RET TOP END

Advertising
This manual is related to the following products: