PA SERIES PUMPS

OM−04402

PAGE A − 1

SAFETY

SAFETY - SECTION A

This information applies to Prime Aire

R

Series pumps. Refer to the manual ac-
companying the engine or power
source before attempting to begin oper-
ation.

Because pump installations are seldom
identical, this manual cannot possibly
provide detailed instructions and pre-
cautions for each specific application.
Therefore, it is the owner/installer’s re-
sponsibility to ensure that applications
not addressed in this manual are per-
formed only after establishing that nei-
ther operator safety nor pump integrity
are compromised by the installation.

Before attempting to open or service the
pump:

1. Familiarize yourself with this man-

ual.

2. Shut down the engine and discon-

nect the positive battery cable, or
lock out incoming power to the mo-
tor and take precautions to ensure
that the pump will remain inopera-
tive.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature and make

sure the pump is cool before open-
ing any covers, plates, or plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau-

tiously.

7. Drain the pump.

If the pump is equipped with the auto-
matic starting system, it is subject to au-
tomatic restart. Keep hands and cloth-

ing away from the unit to prevent injury
during automatic operation. Disconnect
the positive battery cable before per-
forming any maintenance. Failure to do
so may result in serious personal injury.

This pump is designed to handle most
non-volatile, non-flammable liquids
containing specified entrained solids.
Do not attempt to pump volatile, corro-
sive, or flammable liquids which may
damage the pump or endanger person-
nel as a result of pump failure.

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment. Attach lifting equip-
ment to the lifting device fitted to the
pump. If chains or cable are wrapped
around the pump to lift it, make certain
that they are positioned so as not to
damage the pump, and so that the load
will be balanced. The bail is intended for
use in lifting the pump assembly only.
Suction and discharge hoses and pip-
ing must be removed from the pump be-
fore lifting.

After the pump has been installed, make
certain that the pump and all piping or
hose connections are tight, properly
supported and secure before operation.

Do not operate the pump against a
closed discharge valve. If operated