Troubleshooting – Gorman-Rupp Pumps 4D-X3 1P User Manual

Page 14

Advertising
background image

TROUBLE

POSSIBLE CAUSE

PROBABLE REMEDY

PUMP FAILS TO

PRIME

PUMP STOPS OR

FAILS TO DELIVER

RATED FLOW OR

PRESSURE

D SERIES

OM--01515

TROUBLESHOOTING

PAGE D -- 1

TROUBLESHOOTING --- SECTION D

Review all SAFETY information in Section A.

Before attempting to open or service the

pump:
1. Familiarize yourself with this manual.
2. Shut off incoming power to the motor

and lock it out to ensure that the
pump will remain inoperative.

3. Allow the pump to completely cool if

overheated.

4. Close the discharge valve (if used).
5. Drain the pump.

Air leak in suction line.

Correct leak.

Lining of suction hose collapsed.

Replace suction hose.

Integral suction or discharge check

Clean valves, check that flange nuts

valve clogged, binding, or not seating

are tight.

properly.

Cracked or broken diaphragm.

Replace diaphragm.

Diaphragm not securely in place.

Secure diaphragm.

Strainer clogged.

Check strainer and clean if necessary.

Air leak in suction line.

Correct leak.

Suction intake not properly submerged. Check installation.

Lining of suction hose collapsed.

Replace suction hose.

Cracked or broken diaphragm.

Replace diaphragm.

Diaphragm not securely in place.

Secure diaphragm.

Strainer clogged.

Check strainer and clean if necessary.

Integral suction or discharge check

Clean valves, check that flange nuts

valve clogged, binding, or not seating

are tight.

properly.