HOIST AND JACKSHAFT

Carton inventory/Operator specifi cations - Hoist and Jackshaft

OPERATOR SPECIFICATIONS

CARTON INVENTORY

Before beginning your installation check that all components were provided.

DESCRIPTION
Powerhead assembly
Owner’s manual and caution labels
Hardware box (includes fasteners, track spacers, trolley, door arm assembly, front idler and header mounting bracket)
3-Button control station with LED
Hoist hand chain (Models H, HJ and GH ONLY)
Door sprocket
Door/operator drive chain
Entrapment Protection Device: Model CPS-U photoelectric sensors (standard)

HOIST AND JACKSHAFT OPERATORS

MOTOR

TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous duty
HORSEPOWER:
Model J, H and HJ . . . . . . . . . . . . . . . . 1/3, 1/2, 3/4 and 1 HP
Model GH . . . . . . . . . . . . . . . . . 1/2, 3/4, 1, 1-1/2, 2 and 3 HP
SPEED:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1725 RPM
VOLTAGE:
Model J, H and HJ . . . . . . . . . . . . . . . . . . . .115/230V 1 Phase

208/230/460/575V 3 Phase

Model GH . . . . . . . . . . . . . . . . . . . . . . . . . .115/230V 1 Phase

208/230/460/575V 3 Phase

CURRENT (Amperage):
Models H, HJ, and J
Voltage-Phase

1/3 HP

1/2 HP

3/4 HP

1 HP

115-1Ø, 60Hz

8.5

11.2

13.6

16

230-1Ø, 60Hz

4.2

5.6

6.8

8

208/230-3Ø, 60Hz

3

3.1

4

6

460-3Ø, 60Hz

1.5

1.75

2

3

575-3Ø, 60Hz

1.3

1.4

1.6

1.8

Model GH
Voltage-Phase 1/2 HP 3/4 HP 1 HP 1-1/2 HP 2 HP 3 HP
115-1Ø, 60Hz

11.2

13.6

16

20

-

-

230-1Ø, 60Hz

5.6

6.8

8

10

-

-

208/230-3Ø, 60Hz 3.1

4

6

7

8

10.6

460-3Ø, 60Hz

1.75

2

3

3.5

4

4.8

575-3Ø, 60Hz

1.4

1.6

1.8

2.75

3

-

ELECTRICAL

TRANSFORMER:. . . . . . . . . . . . . . . . . . . . . . . . 24Vac Secondary
CONTROL STATION:. . . . . . . . . . . . . . . . NEMA 3-Button Station

Open/Close/Stop w/LED

WIRING TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . C2 (Standard)

Momentary contact to OPEN and STOP, constant pressure to

CLOSE, plus wiring for sensing device to reverse and auxiliary

devices to open and close with open override. See page 29 for

optional wiring types and operating modes.

LIMIT ADJUST:. . . . . . . . . . Linear driven, fully adjustable screw

type cams. Adjustable to 24 feet.

SAFETY

DISCONNECT:
Model J . . . . .Floor level disconnect for manual door operation
Model H and GH . . . . . . . Floor level chain hoist with electrical

interlock for manual door operation

Model HJ . . . . . . . . . . . . . . Includes both floor level disconnect

systems stated above

ENTRAPMENT PROTECTION:
LiftMaster Monitored Entrapment Protection (LMEP)
Photoelectric Sensors (CPS-U): . . . . . . . . . . . . .Through beam

used to provide non-contact safety protection.

Safety Edge (Optional): . . . . . . . Electric or pneumatic sensing

device attached to the bottom edge of door.