Mount the photoelectric sensors (provided), Entrapment protection, Cps-u and cps-un4 – LiftMaster J door operator User Manual

Page 22: Cps-ei

Advertising
background image

22

ENTRAPMENT PROTECTION

MOUNT THE PHOTOELECTRIC SENSORS (PROVIDED)

Center each sensor in the bracket with the lenses pointing
toward each other across the door.

Attach the sensors to the brackets with the provided
hardware. Finger tighten the receiving sensor wing nut.
Securely tighten the sending sensor wing nut.

Run the wires from both sensors to the operator. Use
insulated staples to secure wire to the wall and ceiling.

Connect the sensor wires to the operator (see below).

1

2

3

4

Wire

Indicator Light

“C” Wrap

Wing Nut

Hex Bolt 1/4-20x1-1/2"

Sensor

Photoelectric Sensor
6" (15 cm) max. above fl oor

Photoelectric Sensor
6" (15 cm) max. above fl oor

Invisible Light Beam Protection Area

Bell Wire

Secure wire with
insulated staples

Connect wire to
Operator (refer to
following page)

Entrapment Protection

WIRE THE LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICES

Connect the LiftMaster Monitored Entrapment Protection
(LMEP) device to the logic board according to the models
shown below:

1

TTC

24VAC

24VAC

LMEP:

EDGE:

OPEN

CLOSE

STOP

COMMON

MAS

COMMON

TIMER

DEFEAT

POWER

TIMER

ENABLE

3

FSTS

DIAG

TS

3-PHASE

1-PHASE

White (Blue)

White/Black (Brown)

CPS-U and CPS-UN4

40-34141-1

LMEP2

LMEP1

E1

E2

E3

E4

CPS-EI

24VAC

LMEP

EDGE

OPEN

CLOSE

STOP

COMMON

SBC

MAS

COMMON

TIMER

DEFEAT

POWER

Green LED

4-Wire Sensing Edge

Black

Black

White

White

CPS-EI