TIMER-TO-CLOSE

PROGRAM TIMER-TO-CLOSE BY EXAMPLE (Method 2):
TO PROGRAM:
1. Close the door.
2. Turn the selector dial to PROGRAM.
3. Press and hold TIMER button for 5 seconds until OPEN and

OLS flashes then release.

4. Press and release the OPEN button and wait for the door to

reach full open or mid stop position.

5. Wait for desired amount of time to pass. (An internal stop

watch starts counting when the door stops moving.)

6. Press and release the TIMER button, CLOSE button or STOP

button to stop the timer. (TIMER SET LED will turn on.)

7. Turn the selector dial to the desired wiring type (T, TS, FSTS).
NOTE: To read back the Timer-To-Close setting, turn the selector
dial to DIAGNOSTIC and press the TIMER button. The OPEN LED
will flash once for every second programmed and the CLOSE LED
will flash once for every 15 seconds programmed.
In T Mode, timer can be deactivated from the open position by
pressing the STOP button. The timer will be reactivated on the
next operation command. The STOP button WILL NOT deactivate
the timer in the TS mode. To deactivate the timer for more than
one cycle in T mode or in TS mode, attach a defeat switch to 11
and 12 (COMMON and TIMER DEFEAT).
Reminders: FSTS wiring mode allows the Timer-To-Close to be
activated by the Single Button Control (terminal 1) only. T wiring
mode allows the door to attempt to close only one time for safety
purposes.

Operation will vary
depending on wiring type

SELECTOR DIAL

CAR DEALER MODE

Feature: The car dealer mode uses the SBC (Single Button Control
input) to bring the door from a closed position to the programmed
Open Mid-Stop position and keep it at that location even with
multiple inputs.
Benefit: Provides energy cost savings by limiting the door
opening height.
Requirements: This feature works in conjunction with the
programmable Timer-To-Close feature. To enable this feature you
must first connect a treadle, photoelectric sensor or loop detector
accessory to the SBC input and must have at least one LiftMaster
Monitored Entrapment Protection (LMEP) device installed (refer to
page 20). Wiring type must be set to TS or T.
TO PROGRAM:
1. Start with the door in the closed position.
2. Turn the SELECTOR DIAL to PROG.
3. Push the TIMER button and release (Green Timer LED will

be lit).

4. Push the MID button and release. This turns on the Car Dealer

Mode. (The GREEN TIMER LED will flash 6 times indicating the
Car Dealer Mode is turned on.)

5. Push the TIMER button and release.
6. Turn the SELECTOR DIAL to the desired wiring type (TS or T).
NOTE: To disable the Dealer Mode follow steps 2 and 3, then
press the MRT button and release. (The GREEN TIMER LED will
flash 3 times indicating that the Car Dealer Mode is off.)