Maintenance, Maintenance schedule, Life of operator feature (odometer/cycle counter) – LiftMaster J door operator User Manual

Page 36: Brake (if present), How to order repair parts

Advertising
background image

36

MAINTENANCE

MAINTENANCE

MAINTENANCE SCHEDULE

For use with Maintenance Alert System.
Check at the intervals listed in the following chart:

HOW TO ORDER REPAIR PARTS

OUR LARGE SERVICE ORGANIZATION SPANS AMERICA

Installation and service information are available.

Call our TOLL FREE number:

1-800-528-2806

www.liftmaster.com

6 Use SAE 30 Oil (Never use grease or silicone spray).
• Do not lubricate motor. Motor bearings are rated for

continuous operation.

• Do not lubricate clutch or V-belt.
 Repeat ALL procedures.
z Inspect and service whenever a malfunction is observed or

suspected.

To avoid SERIOUS personal INJURY or DEATH:
• Disconnect electric power BEFORE performing ANY

adjustments or maintenance.

• ALL maintenance MUST be performed by a trained door

systems technician.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

WARNING

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

LIFE OF OPERATOR FEATURE (ODOMETER/CYCLE COUNTER)

The operator is equipped with an odometer to show how many months and cycles the operator has performed from the time it as
installed. This feature can help determine how long the operator has been in service.
1. Start with the door in the closed position.
2. Turn the SELECTOR DIAL to DIAG (diagnostic mode).
3. Press and release the MAS button on the logic board.
4. Press and release the MRT button on the logic board.
5. The open and close lights will flash. OPEN for every 5,000 cycles and CLOSE for every 3 months.
6. Return the SELECTOR DIAL to the desired wiring type.
NOTE: If the operator has not reached 5,000 cycles or 3 months, there will be no indications.

EVERY 3

MONTHS OR

5,000 CYCLES

z6

z

z6

EVERY MONTH

z

EVERY 6

MONTHS OR

10,000 CYCLES

z

z

z

z

EVERY 12

MONTHS OR

20,000 CYCLES











ITEM

Drive Chain

Sprockets

Clutch

Belt

Fasteners

Manual Disconnect

Bearings and Shafts

LiftMaster Monitored
Entrapment Protection
(LMEP)

PROCEDURE

Check for excessive slack.
Check and adjust as required.
Lubricate.

Check set screw tightness.

Check and adjust as required.

Check condition and tension.

Check and tighten as required.

Check and operate.

Check for wear and lubricate.

Check alignment and
functionality.

BRAKE (IF PRESENT)

A solenoid brake is available as an option for some models. The
brake is adjusted at the factory and should not need additional
adjustment for the life of the brake assembly.

Inspect the brake pad and replace brake assembly when
necessary.
NOTE: Your operator may look different than the operator shown.