Wiring diagrams, Logic (ver. 4.0) 1 phase wiring diagram, Cb a – LiftMaster J door operator User Manual

Page 41

Advertising
background image

41

WIRING DIAGRAMS

Wiring Diagrams

C1

C8

C61

SLOT 1

RADIO

SLS

MR

T

MID

TTC

DA

T

A

24V

A

C

14

13

12

11

10

6

7

8

9

5

4

3

2

1

24V

A

C

LMEP:

EDGE:

OPEN

CLOSE

ST

OP

COMMON

RELA

Y A

RELA

Y B

SBC

MAS

COMMON

TIMER

DEFEA

T

PO

WER

TIMER

ENABLE

12

3

FSTS

DIA

G

OPTN

PR

OG

TT

S

E2

D1

C2

B2

CLS

OLS

MID

REV

STD

SLOT 2

MOTOR

DIRECTION

3-PHASE

1-PHASE

Remove Jumper

To Install External

Door Interlock

3-Button Station

Maintenance

Alert LED

(RD) (WH)

Open

Close

Stop

Open/Close

Single Button

Sensing

Edge

Refer to page 26 for
LiftMaster Monitored
Entrapment Protection (LMEP)
device connections

Hoist Interlock

When Present

TMR DEF

SWITCH

MOV

MOV

(YE)

(BL)

(YE)

(OR)

(WH)

(YE)
(PU)

(WH)

(RD)
(GY)
(YE)
(RD)

(WH)

(PU)
(YE)
(OR)

(GY)

(OR) (PU)

(WH)
(WH)

(WH)

(WH)

(WH)

(PU)

(YE)

(WH)

(WH)

(WH)

(WH)

(YE)

115 / 230

VOLT 1PH.

POWER IN

hot

neutral

ground

(BK)

COM

120

VAC

120 / 240

VAC

+24 VAC

-24 VAC

See Motor

Connections

8

0

1

4

6

2

6

2

8

4

0

1

COIL

COM

NO

C

B

A

(WH)

(BL)

(GY)

(YE)

(BR)

(GY)

See Motor

Connections

NOTE: Lock Sensor is provided on Models
DJ and DH only, red wire from main harness
connects to NC on Bypass L/S and to NO on
LOCK SENSOR switch. White wires connect the
COM on BYPASS L/S and LOCK SENSOR switch
to NC on Open L/S.

NOTE: The Lock Sensor switch is
located in the chassis.

OPEN

CLOSE

STOP

NOTE: Gray (GY) and purple (PU) motor wires are reversed
for H and HJ right hand models and all GH and J models.

115V MOTOR CONNECTION

230V MOTOR CONNECTION

(WH)

(WH)

(WH)

(RD)

(PU)

(YE)

COM

NO

NC

NO

NC

COM

NO

NC

COM

OPEN L/S

NO

NC

LOCK

SENSOR

(see note at left)

CLOSE L/S

SAFETY L/S

(WH)

(RD)

(WH)

(RD)

(WH)

(RD)

(YE)

(GY)

1 2 3 4

RPM Board

L3 L2 L1

COM

NO

NC

BYPASS

L/S

(WH)

External Radio Receiver

NOTE: 32 Vdc power supplied
from White and Yellow wires located
within the electrical box.

(WH)

(OR)

(YE)

R1

R2

R3

LOGIC (VER. 4.0) 1 PHASE WIRING DIAGRAM

WIRING DIAGRAMS

Refer to page 22 for
LiftMaster Monitored
Entrapment Protection (LMEP)
device connections

Advertising