CONTROL CONNECTION DIAGRAM

IMPORTANT NOTES:
1. The 3-Button Control Station provided must be connected for operation.
2. If a STOP button is not used, a jumper must be placed between terminals 4 and 5.
3. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation
with the Commercial Door Operator.

3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON

2 OR MORE

KEY LOCKOUT

R1

R2

R3

7

6

4

5

Stop

Close

Open

Stop

Close

Open

7

6

4

5

Stop

Close

Open

2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER

STANDARD

7

6

4

Close

Open

D1 & E2

MODE ONLY

2 OR MORE

7

6

4

Close

Open

Close

Open

D1 & E2

MODE ONLY

OPEN / CLOSE

1

4

B2, T, TS & FSTS

MODE ONLY

1 BUTTON STATION OR ANY AUXILIARY DEVICE

RADIO CONTROLS

EXTERNAL
RADIO RECEIVER

NON-MONITORED SENSING DEVICE TO REVERSE OR STOP

EXTERNAL INTERLOCK

11

8

2

3

2

3

Remove Factory Installed Jumper

When Interlock is Used

ONE

2 OR MORE

STANDARD

7

6

4

5

Stop

Close

Open

All Wiring Types

Keyswitch

Sensing Device

10

Maintenance

Alert LED

10

10

Maintenance

Alert LED

Maintenance

Alert LED

(RED)

(WHITE)

(RED)

(WHITE)

(RED)

(WHITE)

Note: 11 and 4 are both the same common.

Either is acceptable.

See note 2.

See note 2.

See note 2.

TIMER DEFEAT SWITCH

NOTE: 32 Vdc power supplied from white
and yellow wires located within the
electrical box.

NOTE: Stop circuit must be wired in series for
all stop buttons to function. This may require
removal of factory installed jumper bar in the
3-button station.

Keyswitch

11 12

(WH) (OR) (YE)