Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-3112-3000

24 VAC

100 ohm DIN

250°C

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6RW 0250 AAAA A

6, 8

146E-3112-3000

24 VAC

100 ohm DIN

482°F

High Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6PW 0482 AAAA A

6, 8

146E-3112-4000

24 VAC

100 ohm DIN

250°C

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6RY 0250 AAAA A

6, 8

146E-3112-4000

24 VAC

100 ohm DIN

482°F

Low Limit

Auto Reset

8A Relay

Fixed

DIN Rail

LF G6PZ 0482 AAAA A

6, 8

146E-3601-1000

24 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6HU 0032 0600 A

6, 8

146E-3601-1000

24 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6JU 0000 0315 A

6, 8

146E-3601-1N00

24 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0032 0600 A

2, 6, 8

146E-3601-1N00

24 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU 0000 0315 A

2, 6, 8

146E-3601-1P00

24 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0032 0600 A

2, 6, 8

146E-3601-1P00

24 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU 0000 0315 A

2, 6, 8

146E-3601-1S00

24 VAC

J t/c

32 to 600°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0032 0600 A

2, 6, 8

146E-3601-1S00

24 VAC

J t/c

0 to 315°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU 0000 0315 A

2, 6, 8

146E-3601-2000

24 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6HY 0032 0600 A

6, 8

146E-3601-2000

24 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6JY 0000 0315 A

6, 8

146E-3601-2N00

24 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0032 0600 A

2, 6, 8

146E-3601-2N00

24 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0000 0315 A

2, 6, 8

146E-3601-2P00

24 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0032 0600 A

2, 6, 8

146E-3601-2P00

24 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0000 0315 A

2, 6, 8

146E-3601-2S00

24 VAC

J t/c

32 to 600°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HY 0032 0600 A

2, 6, 8

146E-3601-2S00

24 VAC

J t/c

0 to 315°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JY 0000 0315 A

2, 6, 8

146E-3601-3000

24 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6HW 0032 0600 A

6, 8

146E-3601-3000

24 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6JW 0000 0315 A

6, 8

146E-3601-3N00

24 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0032 0600 A

2, 6, 8

146E-3601-3N00

24 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0000 0315 A

2, 6, 8

146E-3601-3P00

24 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0032 0600 A

2, 6, 8

146E-3601-3P00

24 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0000 0315 A

2, 6, 8

146E-3601-3S00

24 VAC

J t/c

32 to 600°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HW 0032 0600 A

2, 6, 8

146E-3601-3S00

24 VAC

J t/c

0 to 315°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JW 0000 0315 A

2, 6, 8

146E-3601-4000

24 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6HZ 0032 0600 A

6, 8

146E-3601-4000

24 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV G6JZ 0000 0315 A

6, 8

146E-3601-4N00

24 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0032 0600 A

2, 6, 8

146E-3601-4N00

24 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ 0000 0315 A

2, 6, 8

146E-3601-4P00

24 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0032 0600 A

2, 6, 8

146E-3601-4P00

24 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ 0000 0315 A

2, 6, 8

146E-3601-4S00

24 VAC

J t/c

32 to 600°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5HZ 0032 0600 A

2, 6, 8

146E-3601-4S00

24 VAC

J t/c

0 to 315°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV G5JZ 0000 0315 A

2, 6, 8

146E-3602-1000

24 VAC

J t/c

32 to 1382°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6HU 0032 1382 A

6, 8

146E-3602-1000

24 VAC

J t/c

0 to 750°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV G6JU 0000 0750 A

6, 8

146E-3602-1N00

24 VAC

J t/c

32 to 1382°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0032 1382 A

2, 6, 8

146E-3602-1N00

24 VAC

J t/c

0 to 750°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5JU 0000 0750 A

2, 6, 8

146E-3602-1P00

24 VAC

J t/c

32 to 1382°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV G5HU 0032 1382 A

2, 6, 8