2 optional specifications, Optional specifications -2 – Yokogawa EJA115 User Manual

Page 38

Advertising
background image

IM 01C22T03-00E

9-2

9. GENERAL SPECIFICATIONS

9.2 Optional Specifications

For items other than those described below, refer to

the appropriate user’s manual.

Item

Description

Code

Factory Mutual (FM)

CENELEC ATEX (KEMA) Flameproof Approval *

2

Certificate: KEMA 02ATEX2148

II 2G EEx d IIC T4, T5 and T6, Amb. Temp.:

Ϫ

40 to 80

Њ

C (

Ϫ

40 to 176

Њ

F) for T5,

Ϫ

40 to 75

Њ

C (

Ϫ

40 to 167

Њ

F) for T4 and T6

Max. process Temp.: T4; 120

Њ

C (248

Њ

F), T5; 100

Њ

C (212

Њ

F), T6; 85

Њ

C (185

Њ

F)

Enclosure: IP67

CENELEC ATEX Type n Approval *

2

II 3G Ex nL IIC T4, Amb. Temp. –40 to 60

°

C (–40 to 140

Њ

F), Enclosure: IP67

Ui=32V, Ci=3.52 nF, Li=0

µ

H

CENELEC ATEX (KEMA) Intrinsically Safe Approval *

2

Certificate: KEMA 02ATEX1344X

[Entity model]

II 1G EEx ia IIC T4, Amb. Temp.:

Ϫ

40 to 60

Њ

C (

Ϫ

40 to 140

Њ

F)

Ui=24.0 V, Ii=250 mA, Pi=1.2 W, Ci=1.76 nF, Li=0

H

[FISCO model]

II 1G EEx ia IIC T4, Amb. Temp.:

Ϫ

40 to 60

Њ

C (

Ϫ

40 to 140

Њ

F)

Ui=17.5 V, Ii=360 mA, Pi=2.52 W, Ci=1.76 nF, Li=0

H

II 1G EEx ia IIB T4, Amb. Temp.:

Ϫ

40 to 60

Њ

C (

Ϫ

40 to 140

Њ

F)

Ui=17.5 V, Ii=380 mA, Pi=5.32 W, Ci=1.76 nF, Li=0

H

Enclosure: IP67

KF25

KN25

CF15

KS25

CENELEC ATEX

FF15

FS15

FM Explosionproof Approval *

1

Explosionproof for Class I, Division 1, Groups B, C and D

Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G

Hazardous (classified) locations, indoors and outdoors (NEMA 4X)

Temperature class: T6 Amb. Temp.:–40 to 60

°

C (–40 to 140

°

F)

FM Intrinsically Safe Approval *

1

[Entity Model]

Cl. I, II&III, Division 1, Groups A, B, C ,D, E, F&G, Temp. Cl. T4 and Cl. I, Zone 0,
AEx ia IIC, Temp. Cl. T4
Groups A, B, C, D, E, F&G and Group IIC:

Vmax.= 24 V, Imax.= 250 mA, Pi= 1.2 W, Ci= 3.52 nF, Li= 0

µ

H

[FISCO Model]

Cl. I, II&III, Division 1, Groups A, B, C, D, E, F&G, Temp. Cl. T4 and Cl. I, Zone 0,
AEx ia IIC, Temp. Cl. T4
Groups A, B, C, D, E ,F&G and Group IIC:
Vmax.= 17.5 V, Imax.= 360 mA, Pi = 2.52 W, Ci = 3.52 nF, Li = 0

µ

H

Groups C, D, E, F&G and Group IIB:

Vmax.= 17.5V, Imax. = 380 mA, Pi = 5.32W, Ci = 3.52 nF, Li = 0

µ

H

Nonincendive for Cl. I, Division 2, Groups A, B, C&D, Temp. Cl. T4

and Cl. I, Zone 2, Group IIC, Temp. Cl. T4
and Cl. II, Division 2, Groups F&G Temp. Cl. T4
and Cl. III, Division 2, Temp. Cl. T4
Vmax.= 32 V, Ci = 3.52 nF, Li = 0

µ

H

Enclosure: “NEMA4X”, Amb. Temp.: –40 to 60

°

C (–40 to 140

Њ

F)

T0903.EPS

CSA Explosionproof Approval *

1

Certificate: 1010820

Explosionproof for Class I, Division 1, Groups B, C and D

Dustignitionproof for Class II/III, Division 1, Groups E, F and G

Temp. Class: T4, T5, T6 Encl Type 4x Amb. Temp.: –40 to 80

°

C (–40 to 176

°

F)

Max. Process Temp.: T4; 120

°

C (248

°

F), T5; 100

°

C (212

°

F), T6; 85

°

C (185

°

F)

Process Sealing Certification
Dual seal certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required. Primary seal failure annunciation : at the zero adjust-
ment screw

Canadian Standards
Association (CSA)

*1:

Applicable for Electrical connection code 2 and 7.

*2:

Applicable for Electrical connection code 2, 4, 7 and 9.

Advertising