Wiring diagram - pro-cut 125, Enhanced diagram – Lincoln Electric IM491 PRO-CUT 125 User Manual

Page 36

Advertising
background image

– 36 –

STATUS BOARD

1

2

3

4

5

6

8

7

211

212

213

214

215

216

218

325

326

1

3

2

R1

10K

5

4

1

2

6

3

5

6

3

7

84

9

2

J2

J8

1

CONTROL BOARD

12

14

10

11

15

16

13

10

1

2

3

4

5

6

7

8

9

319

324

323

322

321

J3

J7

J6

319

PURGE/RUN

SWITCH

(PURGE IS

OPEN)

2

3

4

1

5

6

43

9

1

27

81

2

10

11

12

31

32

G1

381

G2

382

G3

383

G4

384

G5

385

G6

386

J4

2

4

5

3

6

7

8

1

J5

334

335

336

337

2

4

J10

CR2

CR1

SV1

38

CR2

E

389

71

ELECTRODE

PILOT

389

CR2

CR2

388

WORK

W

POS

POS

NEG

71

BYPASS

BOARD

5

6

4

3

9

2

1

8

7

10

12

11

FAN

333

332

24

VAC

31

32

110

VAC

15

3

6

9

12

2

5

8

11

330

331

14

13

24

VAC

334

335

1

4

7

10

MAIN TRANSFORMER

J8

GENERAL INFORMATION

ELECTRICAL SYMBOLS PER E1537

RESISTORS = OHM/WATT (1/2 WATT UNLESS

OTHERWISE SPECIFIED)

R3

+

-

SCR2

CR1

75

76

77

390

391

388

208

C501

D501

NEG

319

5J12

2J12

4J12

1J12

34

222

221

L503

L504

R2

3

300W

N.A.

NOTES

+

POS

14

13

R6

12K

10W

R7

TO PRIMARY

COILS

TS1

CW

TO GROUND

PER NATIONAL

ELECTRICAL CODE

L2

L1

78

78

380V

TO PRIMARY

COILS

1

3

4

5

6

2

J16

7

8

9

J10, J13

14

12

7

13

11

6

5

10

1

2

9

8

4

3

31

37

34

36

32

+

31

7

9

3

4

5

6

2

1

8

328

327

35

602

601

603

604

606

605

J16

HI FREQ MODULE

1

2

3

606

605

J11

1

2

3

4

392

393

394

31

32

20

VAC

J17

306

607

608

C1

20K

5W

R4

J13

1

7

28

3

9

10

4

5

11

6

12

J14

SCR4

SCR6

AC1

AC2

AC3

SCR3

SCR5

SCR1

S1

TO PRIMARY

COILS

TO SUPPLY

LINES

440/460V

TO GROUND

PER NATIONAL

ELECTRICAL CODE

TO GROUND

PER NATIONAL

ELECTRICAL CODE

TO PRIMARY

COILS

S1

TO SUPPLY

LINES

220/230V

U

V

W

T1

T2

T3

T2

T3

U

V

W

TO PRIMARY

COILS

CONNECTOR CAVITY NUMBERING

SEQUENCE. (VIEWED FROM

COMPONENT SIDE OF BOARD)

N.A.

NOZZLE (PILOT LEAD AT

THE TORCH).

607

31

B

B

B

R

RR

72

J12, J18

J17

4

1

4

3

6

2

5

J18

J18 PIN 3 CONNECTS TO THE

4

90W

J31

J5, J31

3

300W

R5

70

R8

9

11

6

51

2

8

10

4

7

T2

T1

T3

9

11

6

5

12

8

10

4

7

T2

T1

T3

9

11

6

5

12

8

10

4

7

T2

T1

T3

20

100W

TP1

TP2

TP3

TP1

TP2

TP3

T1

S1

TO SUPPLY

LINES

T2

T3

U

V

W

TP1

TP2

TP3

T1

PN25098

L10261

WIRING DIAGRAM - PRO-CUT 125

SV2

N.B.

N.B. NOT PRESENT ON SOME EARLY

MODELS.

OUTER

PRI.

INNER

PRI.

PRESSURE

SWITCH

PRIMARY

COIL

THERMOSTAT

SAFETY

RESET

S3

OUTPUT

CONTROL

SCR MODULE

P.C. BD.

HI FREQ

ASBLY.

72

J6, J14, J23

2D

4D

POS-D

J5

OPTION

JUMPER

HALF OF

J12 OPTION

JUMPER

LOCAL

REMOTE

76D

76B

76C

4A

40

1

40

2

POS-D

400D

32D

31D

321D

2D

4D

212D

76D

1

OPTION

BOARD

J23

J19

2

3

4

5

6

7

8

9

4

9

2

7

5

10

2A

4A

403

404

212D

400D

76C

76B

OPTION

JUMPER

J8

32D

31D

OPTION

JUMPER

J10

OPTION

HARNESS

10

11

12

HALF OF

OPTION

JUMPER

J12

380VAC

H1

H2

H3

1

3

6

J15

H1

H2

OPTIONAL

REMOTE/LOCAL

SWITCH

OPTIONAL

CNC & GMF

INTERFACE KIT

OR 575V

230/460V

220/380/440V

CONNECTION

575V CONNECTION

J2, J15

J3, J19

J4, J7,

J11, J25

77D

OPTION

JUMPER J2

77D

40

3

40

4

2A

PO

S

40

5

NE

G

75

76

4B

2B

OPTIONAL

TERMINAL

STRIPS

76

75

401

402

2B

4B

POS

405

NEG

3

8

6

1

1

2

3

J25

321D

324D

324D

15

100W

A

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diag

ram for a particular code is pasted inside

the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. G

ive the equipment code number..

Enhanced Diagram

Advertising