Ggt models ggm models – APW Wyott GGT-48H User Manual

Page 8

Advertising
background image

8

CONVERSION:

Instructions are for conversion from Natural Gas to Propane (L.P.) on all GGT & GGM models .
The conversion should be done before connecting the unit to the gas supply.

1. Remove the knobs and front panel.

2. Remove the supply tubes that go

between the thermostats and the

orifice bracket.

2. Unscrew bolts and pilot valve,

then remove the manifold.

3. Unscrew and remove the orifice

fittings from the valve. Change the

orifices to the size recommended

for propane (L.P.). For units with a

pilot safety valve you must also

change the pilot orifice to the other

pilot orifice supplied.

GGT Models

GGM Models

4. Replace the orifice fittings into

the valve.

5.Replace the front panel and knobs.

7. Continue with installation.

6. Before installing the regulator,

unscrew the octagonal cap. With the

brass portion of the cap up, you can

read (NAT) on the plastic insert. Snap

the insert out of the cap, flip it over

and snap back in place. You can now

read (L.P.).

Regulator with Brass Cap

Note: Unit Number on

Side of Orifice Fittings

Plastic Insert

Note: Markings on Insert

L.P. Position of Insert

Advertising