Restart service, Reject program admin login, Win32disableacceptex – HP Integrity rx4640 Server User Manual

Page 67: Enable/disable ssl v2, Log rotations, Rotate log size, Maximum number of threads allowed

Advertising
background image

Restart service

Restart the HP SMH on completion of applying the new configuration settings.

smhconfig -r|--restart

Reject Program Admin Login

Reject or accept and HP Web-enabled System Management Software or VCA login request.

smhconfig -j|--reject-prog-admin-login [=] true|false

Win32DisableAcceptEX

AcceptEX() is a Microsoft WinSock v2 API that provides performance improvements over the use of the BSD
style accept() API in specific circumstances. Some popular Windows products, typically virus scanning or
virtual private network packages, have bugs that interfere with the operation of AcceptEx(). If you encounter
an error condition like:

[error] (730038) An operation was attempted on something that is not a socket::

winnt_accept: AcceptEx failed. Attempting to recover.

Use the following directive to disable the use of AcceptEx():

smhconfig -w|--win32-disable-acceptex [=] True | False

NOTE:

Win32DisableAcceptEX is only available on Windows operating systems.

Enable/disable SSL v2

By default the HP SMH has SSL v2 disabled. Use the following switch to re-enable SSL v2:

smhconfig -s|--disable-sslv2 [=] True | False

where

value False enables SSL v2 and value True disables SSL v2

Execute the following command to restart the HP SMH service smhconfig -r.

Log Rotations

Log files can become large and unmanageable. The following switch enables log files to rotate automatically
when they reach 5M (default size). Either the log file is over-written on the next rotation when the option is
off or a new file is created and the previous file is marked as old when the option is on.

smhconfig -A|--rotate-logs [=] 0 | 1 | 2

Where: 0= off, 1 or 2= on.

Rotate Log Size

Log files can become large and unmanageable. The following switch allows the user to set the size of the
log files.

smhconfig -z|--rotate-log-size [=] size

Where size is a value in the range of 1-9MB.

Maximum Number of Threads Allowed

The Maximum Number of Threads Allowed value allows the user to increase or reduce the maximum number
of threads HP SMH creates to handle page requests. The default is 64 for Windows.

NOTE:

Maximum Number of Threads Allowed is only available on Windows operating systems.

smhconfig -M|--max-threads [=] max-number-of-threads

Where max-number-of-threads is a number in the range of 64-512.

Maximum Number of Threads Allowed is only available on Windows.

Restart service

67