Installing the port-based license utility, Reporting iscsi offload status, Hp proliant licensing log and event file – HP NC532m Dual Port 10GbE Multifunction BL-c Adapter User Manual

Page 12

Advertising
background image

Installation and configuration 12

/opt/hp/hp-pel/nalicense -d [-l <logfile>]
Include the -l parameter if you want all the information that normally prints to stdout to be redirected
to the file specified with <logfile>.

Installing the port-based license utility

To install the HP Linux iSCSI Offload Utility on SUSE Linux Enterprise Server systems,

1.

Navigate to the \linux\hp-pbl\hp-pbl-<version>.sles10.linux.rpm file.

2.

Use the following command to install the utility:
rpm -Uvh hp-pbl-<version>.<distro>.linux.rpm

3.

The hp-pbl utility is configured to start on system boot-up; however, you can start it immediately after
installation without rebooting using the following command:
/etc/init.d/hp-pbl start

4.

The hp-pbl configuration file is a text file located at etc/opt/hp/hp-pbl/hp-pbl.conf. The format of
the configurable MAC parameter is documented in the hp-pbl.conf file. If changes are made to the

hp-pbl.conf configuration file, you must restart hp-pbl using the following command:
/etc/init.d/hp-pbl restart

5.

To manually stop the hp-pbl daemon, use the following command:
/etc/init.d/hp-pbl stop

Reporting iSCSI Offload status

To obtain the iSCSI offload status of embedded adapters, use the following command:

/etc/init.d/hp-pbl status
Output example
iSCSI offload licenses available: 4

iSCSI licenses used: 1

LOM

Configured

Enabled

00:19:BB:3C:A0:1C

YES

YES

Where:

o

iSCSI licenses available reports the number of iSCSI offload licenses available.

o

iSCSI licenses used reports the number of iSCSI offload licenses enabled.

o

LOM is the iSCSI capable LOM MACs. If the MAC is not an iSCSI capable LOM, it is not
displayed with the status command. Error messages are entered in the hp-pbl.log file.

o

Configured reports YES when the iSCSI capable LOM MAC is entered in the hp-p bl.conf file
and is reported as NO if it was not entered in the hp-pbl.conf file. An error message is entered in

the hp-pbl.log file if the iSCSI capable LOM MAC is not entered correctly in the hp-pbl.conf file.

o

Enabled reports YES when the iSCSI capable LOM MAC is currently enabled for iSCSI offload
and reports NO when it is not enabled.

HP ProLiant Licensing Log and Event File

All messages are logged to /var/opt/hp/hp-pbl/hp-pbl.log.
Log messages are in the following format:

[TAG] SP [DATE] SP TEXT TAG
Where TAG is one of:
ERROR indicates an error such as a missing hp-pbl.conf file.

Advertising