7.

Enter a new PFC name in the PFC Name box and then select OK. You can use up to 64
characters for an PFC name.

8.

In the Performance Control main window, click Apply. The settings in the window are applied
to the storage system.

Registering a replacement host bus adapter

If a host bus adapter fails, replace the adapter with a new one. After you finish replacement, you
will need to delete the old host bus adapter from the Performance Control main window and then
register the new host bus adapter.

When you add a new host bus adapter rather than replacing an old one, the WWN of the added
host bus adapter is automatically displayed below Non-Monitor for the connected port in the list.
1.

Click Reports > Performance Monitor> Performance Control to open the Performance Control
window.

2.

Click

to change to Modify mode.

3.

In the Performance Control window, click Performance Control. The Performance Control main
window appears.

4.

Select the WWN tab.

5.

In the upper-left tree, select the old host bus adapter (

) from below Monitor and then right-click

the selection.

6.

From the pop-up menu, select Change WWN and PFC Name. The Change WWN and PFC
Name window opens.

7.

Enter the WWN of the new host bus adapter in the WWN combo box.

You can select the WWN of the newly connected host bus adapter in the WWN combo box.

8.

If necessary, enter a new PFC name in the PFC Name box. You can use up to 64 characters
for an PFC name.

9.

Select OK to close the Change WWN and PFC Name window.

10. In the Performance Control main window, click Apply. The settings in the window are applied

to the storage system.

64

Performance Control operations