Configuring the tool – HP 2000SA G2-Modular-Smart-Array User Manual

Page 15

Advertising
background image

Configuring the tool

The Settings menu provides options for customizing discovery, including entering network IP
addresses and fields for scheduling the tool to run automatically.

NOTE:

To protect against accidentally changing values, you must first select the Change Credentials

check box to access the parameter fields. After changing any settings, a confirmation pop-up
window appears.

The following parameters can be changed in the Settings menu:

Discovery Options—Network IP values

Local Subnet—(Default) Select this radio button to use the same local Subnet of the host
running the tool.

Range Based—Select this radio button to enter a range of IP addresses to search. (Entries
may not end in .255 or .0.)

I know my array IPs—Select this radio button to enter a specific IP address. To enter
multiple IP addresses, separate each IP address with a comma.

Array Authentication Options—Credentials (password) settings

Use defaults (Default)—Select this radio button for the tool to use the default username
and password that was assigned to the array when shipped from the factory.

Use credentials specified below—Select this radio button to enter a specific username and
password that the Firmware Update Tool uses to access arrays. (Credentials must be
Manage-level or higher.)

Proxy Settings—Network proxy settings for accessing the Internet

Use defaults (Default)—Select this radio button for the system to use a default configuration.

Use configuration specified below—Select this radio button to enter the IP address and
port.

SNMP settings—SNMP community string used for discovering MSA arrays over the network

Use defaults (Default)—Select this radio button to use the default read community string
that was assigned to the array when shipped from the factory.

Use SNMP settings specified below—Select this radio button to enter the Read Community
String value. The default value is “public.”

Scheduler Settings—Values for automatically running the Firmware Update Tool.

Frequency—How often to run the tool. Options include: Once, Daily, Weekly, or Monthly.

Start date—Date to run the Firmware Update Tool for the first time in the schedule. From
the calendar, select the date for the scheduler to run the Firmware Update Tool. If the
selected frequency is Daily, Weekly, or Monthly, also select the last date to run the Firmware
Update Tool.

Start time—Time of day to run the scheduler. Enter the time that you want the scheduler
to begin running. Enter the value in HH:MM:SS format.

System credentials—Enter the user name and password (required only for Windows XP
and Windows Server 2003 environments).

Delete existing scheduler—Select this check box to clear all Scheduler Settings (delete the
scheduler).

Configuring the tool