Set power, Set serial, Set syslog – HP ProLiant DL170e G6 Server User Manual
Page 79
CLI commands 79
—
Numerical values between 0–9
o
SL-APM differentiates a password from an account_name (you have a choice between the two
parameters, but not both) by the fact that the “password” parameter is in quotes while the
account_name parameter is not in quotes. If the account_name parameter is used, then you are
prompted for the new password.
Set power
•
Command:
SET POWER {ON|OFF|ENABLE|DISABLE} {ALL | <PORT#> <DMPORT#> {<NODE#>|ALL}}
where:
ALL is used when the command applies to all nodes. You can also use it when the command applies to
all the server nodes in a particular SL server enclosure.
<PORT#> refers to the SL-APM, PDM1, or PDM2 port numbers.
<DMPORT#> refers to the SL-APM Distribution Module port number or HP Intelligent Modular PDU
Extension Bar outlet number.
<NODE#> refers to the SL server node.
•
Description:
o
Turns power on and off to SL enclosures.
o
SET POWER ALL shows the HP Power Management Controller Utility hardware and firmware
versions as well as the license status of all servers in the enclosures.
Set serial
•
Command:
SET SERIAL <baud rate>
•
Description:
o
Configure the serial console baud rate.
o
Serial access to the CLI will be by default 115200 bits/s, no parity, 8 data bits, and one stop bit
(“115200 N 8 1”). You can configure these parameters through the CLI.
o
Valid baud rates are 300, 1200, 2400, 4800, 9600, 14400, 19200, and 115200.
Set syslog
•
Command:
SET SYSLOG {<ip_address>|NONE}
•
Description:
Sets or clears the sending of SL-APM log messages to a remote syslog server. Local logging is
unaffected.