Interpreting Agent Email Messages

64

Command Console V2.5 User Guide

Example:

WARNING: -
Suncity HSG80 10000000200 HSG80 (SP_MONITOR: MonitorSubsys)

This value never changes for a single controller configuration. It always changes
if either controller in a dual redundant configuration fails.

This digit can have one of three values:

0—Everything is fine.
1—Both controllers are functioning.
2—One of the two controllers failed.

Physically inspect the controllers to verify which one failed, as indicated by a
solid green indicator light (not blinking).

The 10th Digit of the State Change Field (External Factors)

The 10th digit indicates state changes caused by external factors.

Example:

WARNING: -
Suncity HSG80 10000000020 HSG80 (SP_MONITOR: MonitorSubsys)

This digit can have one of three values:

0—Everything is fine.
1—State changed from bad to good.
2—State changed from good to bad.

The 11th Digit of the State Change Field (Logical Units)

The 11th digit reports state changes in logical units.

Example:

WARNING: -
Suncity HSG80 10000000002 HSG80 lun(d100:3) (SP_MONITOR:
MonitorSubsys)

This digit can have one of three values:

0—Everything is fine.
1—A LUN state changed from bad to good.
2—A LUN state changed from good to bad.