Introduction 16

choose which components to install or not install. Additionally, the HP SUM utility enables software

deployment for multiple HP ProLiant servers from a single GUI.
For more information about PSP, see the HP ProLiant Support Pack for Windows and Linux User Guide on

the HP website

(

http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=SupportManu

al&lang=en&cc=us&docIndexId=64179&taskId=101&prodTypeId=18964&prodSeriesId=345557

).

Deploying firmware for ProLiant servers using the HP Smart

Update Firmware DVD

The HP Smart Update Firmware DVD provides a collection of firmware bundles containing HP SUM and

firmware for ProLiant servers in an ISO image that can be used either in offline (either an automatic or

interactive mode), or online (either a scripted or interactive mode). The HP Smart Update Firmware DVD

provides firmware for supported HP ProLiant servers and options. The Firmware DVD contains all the
firmware for the supported HP ProLiant servers including BladeSystem enclosures and Virtual Connect

firmware.

In offline mode, the HP Smart Update Firmware DVD boots a small Linux kernel and enables
firmware updates to occur on a single server using the HP SUM software.

In online mode, users can leverage the autorun utility to launch HP SUM or browse the DVD to the
\hp\swpackages directory and execute it directly.

All firmware smart components are placed in the \hp\swpackages directory for use by HP SUM. If

additional firmware smart components are required, then the HP Smart Update Firmware DVD can be
copied to a USB key, and these additional components added to the \hp\swpackages directory. If HP

SUM supports the type of firmware added, then it is automatically added the next time HP SUM is

executed.

CAUTION:

The HP Smart Update Firmware DVD and its contents must be used only by

individuals who are experienced and knowledgeable with HP SUM. Before using HP SUM to
update firmware, back up the target server, and take all other necessary precautions so that

mission-critical systems are not disrupted if a failure occurs.

NOTE:

Because firmware might be able to update only in online or offline mode for some

components, you might need to execute the HP Smart Update Firmware DVD both online and

offline to update all the firmware in an enclosure.

HP SUM stores host and group information from session to session. However, user names, passwords,

and existing credentials are not stored in a session or from session to session.
Use OA version 2.51 or later to get a list of all major firmware versions deployed in your enclosure, using

the Rack Firmware link on the main OA web page. HP supports the current and two previous versions of

the HP Smart Update Firmware DVD.

NOTE:

The Onboard Administrator and Virtual Connect Ethernet and Fibre Channel Modules

are supported only in online deployments on HP ProLiant servers.

NOTE:

You can add firmware components to the USB drive key in the /hp/swpackages