Hp sum supported firmware for hp integrity servers – HP Integrity rx2660 Servers User Manual

Page 23

Advertising
background image

Introduction 23

If the TPM is detected and enabled with Option

ROM Measuring, the installation is silent; the
/tpmbypass switch is not given, and any firmware

updated must be applied to the server.

No pop-up warning appears. A new log file is

generated
(%systemdrive%\cpqsystem\log\cpqstub.log).

Because the installation is silent, the installation is

terminated and cannot continue.

If the TPM is detected and enabled, the
installation is silent, and the /tpmbypass switch is

supplied.

The installation occurs.

Other scenarios do not affect the normal installation procedure.

Deploying firmware using the HP Smart Update Firmware - HP
Integrity BL860c/BL870c/BL890c i2 Servers Bundles

You can only deploy this firmware in HP SUM, included in their respective Windows and Linux bundles.

For supported HP SUM versions, see "Support and Limitations ("

Obtaining the HP SUM utility

" on page

11

, "

Support and limitations of HP SUM

" on page

11

)".

Deploying firmware to the HP Integrity BL860c/BL870c/BL890c i2 Servers is done remotely and is the
same as deploying other firmware like OA or VC with the following exceptions:

You must specify the IP address of the iLO-3 MP on the server as the target to be updated.

On the Select Items to be Installed screen, you must choose whether you want to Upload and

Activate or Upload but Do Not Activate. If you choose not to activate immediately, the firmware is
only updated when the server is rebooted.

NOTE:

In HP Integrity servers, HP SUM does not support the ability to download the latest

components from ftp.hp.com, as these components are not in the catalog on the HP FTP site.

NOTE:

Use the version of HP SUM that comes with the Integrity Bundle when deploying the

firmware to the HP Integrity BL860c/BL870c/BL890c i2 Servers.

HP SUM supported firmware for HP Integrity servers

Component

Supported

Online System ROM

Yes

FPGA firmware

Yes

iLO-3 MP firmware

Yes

Power Monitor firmware

Yes

Advertising